Novell Message Librarian Data File Version 1.00 COPYRIGHT (c) 1985 by Novell, Inc. All Rights Reserved. #:` ' = K m " Z o _ x " ' 8 I T 0 9 f "o L qIg)o+EjxJjt#(0gm ;ASn[yAB'~2?_zt - = Y p !!!"`""""""#@#R#T### $X$X$_$$$$$%B%%%%%& &Y&&X''6(())o*x***B++H,E-u---...///8//0 0&N0w000O1n1|11111114222333333345556"6y666A7777/88$999.:::::;;<o<<R=========>>>>>>> ??A?Z???@j@@@ A AAA3BOBxBBBBbCCCC-DDDDDDDDDDEE1EEE]EE F*FCFLFYF}FFFFF`GlGGGGHHHHS0HH==HI'IXIIJKJJJJ'KlKKKKKNLcLLVMM+NgNNNNNN;ORO3oO|OZ O3O-P;PUPZPPP\QQQQQQ#R6RNRfRwRR SMSSSS TTwTTTTU%U+UpUUUV VVVVViWSXX7YYDZuZZZZZ[D[[[S\\\]H]]]^H_R_k_____HNetWare Install4.11 There is not enough free memory to run this utility. You need %u bytes more of free memory. Press for help. Upgrade NetWare 3.1x or 4.x You do not have enough free memory for the program help to be loaded. You may continue the installation without help by pressing . Custom installation of NetWare 4.11 Select an information file to viewSelect the type of installation you are performingInstall new NetWare 4.11 RuntimeFor help at any time, press .Create a DOS partitionEnter the server name Server name:Enter IPX Internal Network Number Internal network number: Enter name for this NetWare server. This name must be different from any other server or directory tree name on your network. For guidelines, press .Step 1 in installing a new 4.11 NetWare network Server:(Example: MY_SERVER)IPX internal network number must be between 1 and 8 digits long.(Example: AEFD2498)A unique IPX internal network number is required. You may accept this default or modify it to create a number for your server. For guidelines, press .Format the DOS partitionNo source path has been specified. Specify a source path by pressing .This machine either (1) has no DOS hard disk or (2) has one that has not had SETUP run on it. LoadFILE SERVER NAMEIPX INTERNAL NETFORMAT.COMSelect a Method for Creating a DOS PartitionExit to save filesDisk partition size exceeds the size of the hard disk. Specify a smaller partition size.Disk partition size must be at least 15 MB. Specify a larger size.WARNING!Insert the diskette labeled "%s" in drive A.The DOS partition will now be formatted. The program will try to locate FORMAT.COM in the current source path.Specify the server nameAssign an internal IPX number to the serverContinueINSTALL-4.11-5025: This computer does not have an Intel 80386 or equivalent processor. NetWare 4.11 cannot be installed on this computer.The server name must be between 2 and 47 characters long.DOS partition:If you are installing from NetWare distribution diskettes, when the system restarts, the installation will be restarted. Continue with NetWare installation.Select an option.Loading SERVER.EXE Destination path: Enter the destination path (drive:[directory])Change current destination pathCopy server boot files to the DOS partitionNo destination path has been specified. Specify a destination path by pressing .Source path cannot be identical with the destination path. Change either source or destination path.INSTALL-4.11-5026: There is not enough space in the current destination path for all necessary boot files.The media the files are being copied from is defective. Further execution is not possible.The source file '%s' does not exist. Previous screenUnable to format hard disk. You need to format the hard disk manually.Select an Installation OptionINSTALL-4.11-5020: You have insufficient rights in the specified source path.Manual disk partitioningINSTALL-4.11-5018: You do not have write privileges for this file in the destination path.The destination directory does not exist. Specify a destination path.Automatic disk partitioningInvoking FORMAT.COM...Add this partition and destroy the data on your hard disk?There is not enough space in the destination path to copy all the boot files.Select DOS partition sizeEnter new DOS Partition size (in MB) Size in MB: PartitionINSTALL-4.11-5017: The total space required by files that will be copied is larger than the free space available.Specified destination path does not exist. Enter a destination path by pressing .Copy files to the DOS partitionNetWare-1Specified partition size is not valid. Minimum size: 15 MB.:INSTALL-4.11-5004: Unable to read partition table on the hard disk. Check physical connections to the hard disk.The server boot files will be copied from the source directory to the destination directory. Enter the source path (drive:[directory])Source path: COMMAND.COMSpecified path cannot be found.INSTALL-4.11-5006: Unable to access command processor "%s".COMSPECFile %s could not be found in the current source path.If you want to use the help facility you may exit this utility and free %lu bytes of memory, (by removing unnecessary TSRs). Exit by pressing . Exit to DOSHelpSelectChange current source pathSave and continuePress to continue.This file is on the "%s" diskette.To change the source path, press .Creating a DOS partition will destroy all data and all partitions on your hard disk! If you have any necessary data on your hard disk, exit and save the data NOW. NetWare Installation UtilityDisk Partition Options Insert diskette labeled "%s" in drive %c. Press to continue.Unable to read installation command file "%s".INSTALL-4.11-5014: Unable to load system message file "%s".INSTALL-4.11-5009: Unable to open installation command file "%s".Installation command file "%s" must be version 4.00 or greater.Installation command file "%s" does not contain a version.Installation command file "%s" does not contain a fileset of class INSTALL-4.11-5019: Unable to allocate sufficient memory to proceed. Installation command file "%s" does not contain a "CopyToStartup SERVER.EXE" command.Loading system message file... Loading NetWare Installation Utility... INSTALL-4.11-5029: DOS returned error %d while loading the installation utility "%s". Copying File: 0% 100%Insert the diskette labeled "%s" in drive %c, or press to specify a different path.INSTALL-4.11-5016: File "%s" from the "%s" diskette is missing. Unable to continue.Unable to create a STARTUP.NCF file in the destination directory.Existing disk partitions on C: Start End Size Add commands to AUTOEXEC.BAT to load SERVER.EXE?Retain current disk partitions Create a new DOS partitionUnable to open the file %s found in the existing directory. Installation process cannot not continue.INSTALL-4.11-5007: Unable to access %s.A new partition has been created. The computer will now reboot to allow DOS to recognize the new partition.Press any key to continue.INSTALL-4.11-5013: Unable to load SERVER.EXE. After this program completes you need to load the server manually by typing SERVER.DOS partition (12 bit FATs)XENIX partitionDOS partition (16 bit FATs)Extended DOS partitionDOS Huge partitionNetWare v2.X partitionNetWare partitionUnknown partition typeFree space - -MBThis step will delete any existing data on your hard disk as it prepares the disk for NetWare. If you have any necessary data on your hard disk, exit and save the data NOW.INSTALL-4.11-5003: Unable to create the directory "%s".Do you want to create "%s"?INSTALL-4.11-5021: The destination drive does not exist, is not ready, or is a network drive. The destination path is not valid. Please specify a valid path.A:C:\NWSERVERUnable to modify the existing AUTOEXEC.BAT file.C:Copy locale configuration file to DOS partitionINSTALL-4.11-5008: Unable to load help file.CP/M-86 partition.Unable to create an AUTOEXEC.NCF file in the destination directory.Unable to create the AUTOEXEC.BAT file.REM The following lines were created by the server installation program. REM They will cause the server to come up whenever this computer is booted. FORMATNo files matching "%s" could be found in the source path./S/V:NWDOS/X/U/SInsert the diskette containing COMMAND.COM in drive %c.The server name contains illegal characters.Delete existing NetWare disk partitions and data?INSTALL-4.11-5028: A system error has occurred. Execution cannot continue.Unknown procedureThe description of the error is not available.C:\Enter the path to your existing STARTUP.NCF file. Path: INSTALL-4.11-5011: This utility can only be used for hard disk installation.If you want to create a DOS partition with another utility, you should exit, create the partition, and restart the installation.The NetWare installation utility requires a DOS partition on your hard disk in order to install the NetWare operating system.If you do not want to create a DOS partition on your hard disk, you should exit and perform the installation manually.If you continue, you will be guided through the process of creating a DOS partition on your hard disk.The size of the active DOS partition is %d%s%d MB. It should be at least %d MB to continue with the installation. Press for more information.There is no active DOS partition on the disk. If you want to use an existing partition for the installation, you must designate one of your DOS partitions as active using the FDISK utility. Press for help.*There is no DOS partition on the hard drive. If you desire to continue with this installation, you must create a partition using the FDISK utility, and format it with the FORMAT utility. Press for help.K-410-26 *Indicates the active partitionINSTALL-4.11-5022: The help file for this utility is not the correct version. The IPX internal network number must be greater than 0 and less than FFFFFFFF.Some files may be overwritten and replaced, meaning that you may have sufficient space, but that cannot be determined by the installation utility.Press ENTER to continue, ALT-F10 to exit and delete unnecessary files, or ESCAPE to return to the previous screen.The active partition on the disk is not a DOS partition. If you plan to install on a different partition, or are using a boot manager, it may be possible to continue. Otherwise, use the FDISK utility to select an active partition. Press for help.Proceed without executing existing startup fileThe utility did not find an existing STARTUP.NCF file in the destination directory.Proceed in spite of this condition?OK to invoke existing STARTUP.NCF file?INSTALL-4.11-5027: One of the driver support files, "%s" was not copied. This must be copied by hand at a later time.The specified destination directory does not contain a copy of SERVER.EXE.Enter the path to your existing SERVER.EXE file.Copy StatusDon't look for previous versionIf you are installing from any other source you should restart this program by typing INSTALL.Exit this utility and either set up the computer so DOS can see a disk and/or run SETUP on this machine.VeRsIoN=4.11CoPyRiGhT=(c) Copyright 1994, Novell, Inc. All Rights Reserved.Enter the path to your AUTOEXEC.BAT fileINSTALLThe following drivers were found in the existing startup directory, but were not updated by the installation procedure: INSTALL-4.11-5023: The installation script file contains an unrecognized command "%s".Press here to continueCountry Code:Code Page:Keyboard Mapping:Available Country CodesAvailable Code PagesAvailable Keyboard MappingsNoneNew values are for the server, and will not change your DOS configuration. This is the current DOS configuration. Use these values, or select new ones.If you do not use country information in your DOS configuration, choose country code 1, code page 437.Don't use locale informationAccept locale settingsINSTALL-4.11-5005: The utility was unable to create the LCONFIG.SYS file. You must create this manually. LOAD KEYBChange valueSelect fieldIf your keyboard is not a US English keyboard, also choose a country specific keyboard mapping. The SET Buffers Below 16 Meg=200 command has been added to your STARTUP.NCF. Some device drivers require these additional buffers. You may remove this command from the STARTUP.NCF if you are sure the drivers you are loading do not need these buffers.Also, some drivers require you to disable memory above 16 megabytes while the driver loads. Commands like these may only be used in the STARTUP.NCF file. Command examples: Warning:Do you want to modify, add, or delete any special startup set commands?Previous ScreenEnter any SET COMMANDS specific to your system, exactly as you would in STARTUP.NCF. Specially Required Startup Set CommandsDO NOT specify any load commands for drivers.INSTALL-4.11-5030: An Expanded (EMS) Memory manager is loaded. The server cannot be loaded. Press for help. %s exists as a file, not a directory. It cannot be used as the destination directory.Select the filename format NetWare - allows extended lower case filenames DOS - maps lower case characters to upper case in filenames You must use a shell (e.g. NETX.EXE) rather than a requester (e.g. VLM.EXE), to access lower case extended filenames.The following table shows the %d filename characters which NetWare allows as lower case, but which DOS converts to upper case.INSTALL-4.11-5010: An error prevented the utility from setting the language of the server to the preferred language.INSTALL-4.11-5012: An error prevented the utility from selecting NetWare filenames.The top row represents the NetWare allowable filename character.The bottom row displays the character as it will be converted if you select DOS filenames. NetWare Filename Format DOS Filename Format (recommended) Select the format you desire and press Press for more information.Existing files on this server which contain extended lower case filenames will be mapped to upper case when the volume is mounted, if you select DOS filename format.Press to view upper case mappings, for more information.After finishing with the installation you should "DOWN" the server and reconfigure DOS with the new code page.This will assure that NetWare and DOS use the same code page. INSTALL-4.11-5024: The server needs at least %d kilobytes of free memory to boot. This machine has approximately %d kilobytes of free memory. Press for help. Select a locale configuration for the server, ()...Display Information (README) File The utility was unable to open the information (readme) file. Previous PageNext PagePageThere are no support files for this country code and code page combination. Please select a different country code or code page. IOENGINE NAMEIOENGINE IPX INTERNAL NETUnable to create an IOSTART.NCF file in the destination directory. MSEngine name: MSEngine internal network number: Enter the IOEngine name.Press F5 to select the drivers you desire.Enter the path to your existing IOSTART.NCF file.Unable to open the file %s in the destination directory. Installation process cannot continue.The utility did not find an existing IOSTART.NCF file in the destination directory.No help information is available.The specified destination directory does not contain a copy of MSERVER.EXE.Enter the path to your existing MSERVER.EXE file.Copy selected driversSome of these may only be used in the IOSTART.NCF file. For example: Auto Register Memory Above 16 Megabytes=Off. Enter any SET COMMANDS specific to your system. Enter the commands exactly as you would in IOSTART.NCF.Do you want to invoke your existing IOSTART.NCF file?Don't look for AUTOEXEC.BATInstall NetWare MultiProtocol Router 3.0Upgrade Netware 3.1x or 4.x RuntimeSETUPSpecify the source and destination directoriesThe destination directory is the directory where your existing SERVER.EXE is found. The source directory contains the MPR installation files. Upgrade NetWare MultiProtocol RouterChoose the product you want to installSingle machine running NetWare 4.11.Single machine running as a non-dedicated NetWare 4.11 server and as an OS/2 workstation.Dual machines running dedicated NetWare 4.11 with level 3 system fault tolerance.NetWare 4.11NetWare for OS/2NetWare SFT IIILoading MSERVER.EXE NetWare 4.11 SFT IIIpmloadIn depth explanationsBrief explanationsInformation LevelProduct to be InstalledSimple InstallationUpgrade to NetWare 4.11Install NetWare 4.11 on a new machine, allowing the installation program to make most choices.Upgrade a machine that currently has either NetWare 3.1x or 4.x to NetWare 4.11Select a locale configurationAdd special SET commandsPrompt levelThere is no preceeding help screen.An SFT III License disketteFor help on SFT III installation options press .Exit INSTALL?NoThe processor is already in protected mode. You need to remove or reconfigure your DOS memory manager before installing NetWare.Please WaitThis is the last help screen.Insert the third diskette in drive %c. After you have freed sufficient memory you may restart the installation. Your VLMs are loaded in Extended Memory. This will prevent you from loading the server. You must remove the VLMs from high memory before proceeding. Press for help.No more help is available.NWINSTNCFNWINSTCMDYesPage ForwardPage BackwardError ReportSelect a type of SFT III installationRequirements to install new NetWare SFT III 4.11You must install NetWare SFT III on a new server by first installing NetWare 4.11, then upgrading NetWare 4.11 to NetWare SFT III.Requirements to convert NetWare 4.11 to SFT III 4.11This server machine with NetWare 4.11 completely installedA second server with DOS and a 15 MB minimum DOS partitionA mirrored server hardware link between the two serversEqual memory and disk capacities on both machinesThree blank, formatted, high density, floppy diskettesRequirements to upgrade SFT III 3.11 or SFT III 4.10 to SFT III 4.11NetWare SFT III 3.11 or SFT III 4.10 installed on two machinesConvert NetWare 4.11 to SFT III Upgrade current SFT III to SFT III 4.11 -INSTALL-4.11-5002: The script file does not contain a list of SFT III files to copy. Type of InstallationSFT III requires a separate name for each IOEngine and for the MSEngine, a total of 3 names. The server is known on the network by the MSEngine name.The IOEngine names for this server will be derived from the MSEngine name that you specify. Specify the internal IPX network numbers for the serverSFT III requires separate IPX internal network numbers for each IOEngine and for the MSEngine, a total of 3 numbers. Random values have been specified here.You may accept these defaults or change them as you desire.Modify Network numbers Continue with installation Select the appropriate option Internal IPX Network Numbers Simple installation of NetWare 4.11 The server boot files will be copied to the destination path.(Example: C:\NWSERVER)Choose the destination path:Select FieldEnter a unique name for this NetWare server.Name the new server:The server locale configuration file will be copied from the source directory to the destination directory. MSENGINE NAMEMSENGINE IPX INTERNAL NETCreate diskettes for the other machineYou must have 3 blank formatted diskettes ready for copying files to the other server machine.Insert the first diskette in this machine's floppy drive and specify which drive contains the diskette, then press .Enter the floppy drive letter you desire Floppy drive letter: %c is not a floppy diskette drive. IOINSTLInsert the second diskette in drive %c. Enable read-after-write verify for diskette copy?I2 %s %s %s %s %s Read-after-write verifyMSERVER -sdistrtup.ncf del dmsstrt.ncf Unable to create INSTALL.BAT on floppy diskette.Diskette drive %c does not contain a diskette, or the diskette is write protected, unformatted, or otherwise unusable. Unable to create %s on the floppy diskette. INSTALL-4.11-5015: No files matching the template %s could be found in the destination directory. Install NetWare 4.11 del distrtup.ncf Disable read-after-write verify for diskette copy?cd %s NOTE: During the remainder of this installation, this computer will be referred to as "%.43s_IO1".The other computer will be referred to as "%.43s_IO2".Specify the server name and the destination directoryIMSAThis diskette is not empty. Delete data and proceed? DISK1DISK2Unable to create the DMSSTRT.NCF file in the destionation directory.Do you want to invoke your existing MSSTART.NCF file?del msauto.ncf Insert the next diskette in this machine's floppy drive, then press .DISK3Custom InstallationInstall Netware 4.11 on a new machine, making choices for such things as code page, network number, installation directory, etc.Done EditingThe diskette may be write protected, or in some other manner unuseable. Insert another diskette and retry the operation by pressing or press to cancel this operation.The %c drive may not have enough free space for a NetWare volume. If you have more than one hard drive, or your drive has more than 1024 cylinders, you may proceed. If you have only one hard drive press to review your options.You must run the DOS utilities, FDISK and FORMAT, to partition and format the hard drive. When you have finished, restart the installation process. INSTALL-4.11-5001: An error occurred copying '%s'. Execution cannot continue. Installing SFT III requires the DOS "BUFFERS" value to be at least %d. It is currently set to %d. You must change this in CONFIG.SYS, then reboot the computer before continuing.Unable to open command file %s. Execution will continue without the commands in this file.SET Auto Register Memory Above 16 Megabytes=Off SET Reserved Buffers Below 16 Meg=200SET RESERVED BUFFERS BELOW 16 MEG=200SET AUTOLOAD CLIB=OFF DOMAINThe program should continue normally.Note: Press to see the choices that will be made for you.The size of the active DOS partition is %ld%s%ld MB. It must be at least %ld%s%ld MB to continue with the installation. Press for more information. Unknown code pageThere are no code page support files for this country code. You must select a different country. The utility was unable to delete the file '%s'. Installation cannot be completed. '%s' is not a valid directory name. REM The name of the driver loaded on the following line has changed. REM A new command line has been generated as follows: REM The following line was remarked during upgrade REM set new start address for unclaimed memory block =6291456The SET Reserved Buffers Below 16 Meg=200 command has been added to your IOSTART.NCF. Some device drivers require these additional buffers. You may remove this command if you are sure your drivers do not need these buffers.Some drivers require the memory above 16 megabytes to be disabled while the driver loads. Commands like these may only be used in the IOSTART.NCF file. Command Examples: NWIOSTNCFREM NWNSTLL_Set_CommandsCould not create directory %s Unable to find UnicodePath: label in NETMAIN.ILS.The path %s for the unicode files is invalid.A:\NWSERVERNWMSTNCF