3LINK-ID Readme 02/28/96 -------- Version 2.1 has the following Fixes: - The I/O base address does not display while Bus is ISA+PCI - 3C589/3C589B not been detected while running DOS 6.22 This program attempts to find certain 3Com Ethernet, Token Ring and FDDI adapters in the system in which it is run. For those adapters it is able to find, it will query the adapter and display all user-configurable information that pertains to that adapter model. At present it is able to find and report on the following adapters: - 3C503 EtherLink II - 3C507 EtherLink 16 - 3C5x9 family (3C509, 3C529, 3C579 and 3C589 PCMCIA) EtherLink III - 3C562 PCMCIA LAN+Modem PC-Card - 3C523 EtherLink MC - 3C527 EtherLink MC/32 - 3C59x family (3C590, 3C592, 3C595 and 3C597) EtherLink III Bus Master and Fast EtherLink for EISA/PCI bus - 3C603 TokenLink - 3C6x9 family (3C619, 3C619B, 3C629, 3C629B and 3C679) TokenLink III - 3C77x FDDILink It does not currently find: - 3C501 EtherLink - 3C505 EtherLink Plus - 3C605 TokenLink Plus To run 3LINK-ID, type the program name: 3LINK-ID. There are no command line parameters. 3LINK-ID returns a DOS error code, which may be accessed in a batch file. The error code represents the model of the last 3Com adapter to be found in the system. The models and their codes are: 3C501 1 3C503 2 3C503/16 3 3C505 4 3C507 Coax/AUI 5 3C507 TP/AUI 6 3C523 7 3C527 8 3C509 Coax/AUI 10 3C509 TP/AUI 11 3C509 Coax/TP/AUI 12 3C509 TP only 13 3C579 Coax/AUI 14 3C579 TP/AUI 15 3C579 Coax/TP/AUI 16 3C579 TP only 17 3C529 Coax/AUI 18 3C529 TP/AUI 19 3C529 Coax/TP/AUI 20 3C529 TP only 21 3C509B 24 3C509BTP 25 3C509BC 26 3C509BS 27 3C590 30 3C595 TX 31 3C595 T4 32 3C595 MII 33 3C592 35 3C597 TX 36 3C597 T4 37 3C597 MII 38 3C603 40 3C605 41 3C619 42 3C679 43 3C629 44 3C619B 45 3C629B 46 3C589 50 3C589B 51 3C562 52 3C589C 53 3C770 60 Known limitations: - 3C603 is excluded from the search list as default setting. However, user can use Inclusive search option to search for this kind adapter in the system. - Adapters which have I/O address conflicts may not be found or be reported incorrectly. Example 1: if there are two 3C507 adapters in the system which both have their I/O address set to 300, at least one of the two adapters will not be seen. Example 2: if there is a 3C503 and a 3C507 set to the same I/O address, the Ethernet address and possibly other configuration information will not be reported correctly. - 3LINK-ID has not been tested while running it from the network using IPX or ODI drivers. It has been tested and run successfully from the network while using NDIS 2.01 drivers. - 3LINK-ID has not been tested on Token Ring or FDDI adapters while the adapter is running on the network. - Running 3LINK-ID in an ISA system when a non-3Com adapter is installed and is set for an I/O base in the range of 200 to 3F0 hex may cause unpredictable results, e.g. the system may hang, or lose it's network session. - 3LINK-ID has been tested on all adapters in a DOS environment only. Please send bug reports and comments to Steve Lebus or Philip Chang. FAX: (408) 764-8955 Internet address: Steve_Lebus@3mail.3com.com Internet address: Philip_Chang@3mail.3com.com