YNAdaptec Initial Array Configuration Utility Ver 1.51^Display SCSI Devices Esc = Return to previous menu. F1 = Help toggle.Select Array #^1 Select Array #^2 Select Array #^3 Select Array #^4 This array has not been configured.Assign ^Unit Numbers Adaptec ^SCSISelect Disk ^Array Functions This utility can only be executed from a bootable diskette in A:. Rebootyour system with a bootable diskette in drive A:.Scanning for host adapter/drive information. Please wait.Array MenuInstallation complete.Disk array driveDisplay ^Arrays Add ^New Array Do you want to continue? (y|n) ^Delete Array Press any key to continue.^Replace Array Drive^Initialize Array Displays all devices current connected to the specified board.Run SCSISelect utility to configure/examine SCSI Channel settings.View, Add, Delete, Redefine, and Initialize Arrays.Specify boot array/drive.Up/Down:Move Up/Down Enter :Select Board Esc :Previous MenuArray #%1Aborted!  %1 complete ^Display Array Status Define ^Spare Drives DOS ^Functions Starting SCSISelect for the %1 board.AHA-3985Run DOS Fdisk or DOS Format.Copy ^DriversCopy NetWare or CD-ROM drivers.^Update BIOS Downloads new BIOS to the specified board.DOS ^Format UndefinedDOS F^DISK DOS Format with /s option.DOS Fdisk to to edit partition table Select ^Boot Option ^4KB  ^8KB  ^16KB  ^32KB  ^64KB  12^8KB ^Accept Configuration ^Return to Setup ^Cancel Setup Specify the directory for CD-ROM Drivers installation: (e.g. C:ASPICD) Enter the DOS drive to format: No Arrays DefinedError in copying CD-ROM DriversDisplays status information for all defined arrays. Information includes array type, drive count, drive status, and status of any utility running on the array.Displays status information for the selected array. Information includes array type, drive count, drive status, and status of any utility running on the array.Displays array drive count, drive status, and status of any utility running on the array.Display Array ^Drive Status Press any key to display the next array, or press the Esc key to exit. Display ^Array Overview Displays general information about the selected array, such as array state, array model, unformatted capacity, data block size, drive count, etc.C9BBBACDC8BC%1DABFB3C4C0D9DBCFPlease waitDo you want to exit the Adaptec Initial Array Configuration Utility (y|n) B0Press Any KeyDirectory path for NetWare Drivers installation : (e.g. C:NW) Formatting^CD-ROM DriversNetWare ^3.xx DriversCopy CD-ROM driversCopy NetWare 3.xx Drivers in the directory that contains NetWare.NetWare ^4.xx DriversCopy NetWare 4.xx Drivers in the directory that contains NetWare.Drive MenuType = RAID0RAID0 CVTMirroredRAID3RAID5 RAID5 CVTUninitializedState = Array #%1 is off-line.At least one mirrored pair has a drive down.Non-fault-tolerantFault-tolerantDrives = %1Spare Drive Count = %1Array Physical Capacity = %1MB GB Data Block Size = %1KB Drives available for assignment = %1 RAID Level Min Drive Count Max Drive Count Comments RAID0 2 (3 for CVT) 8 Non-fault-tolerant striped RAID5 3 8 Fault-tolerant striped Mirrored 2 16 Drive count must be even How many members will array #%1 have (excluding spares)? Invalid entry. Valid range is %1 to %2.Counts > 8 are for MIRRORED arrays only and must be an even number.%1 drive(s) available.Are you satisfied with your selections? (y|n) How many spare drives? No RAID Boards Found. If Array Configuration complete, restart the server using Ctrl+Alt+Del. Press any key to continue with Array ConfigurationDOS Unit number for array #%1: DOS Unit Numbers can range from 80 to 87: Boot Array = YesYou must assign members to this array before selecting the next array.You must define at least one array before proceeding.Array #%1Spare too small.I Up/Dn: Move Up/Down Enter: Select Array Esc : Previous MenuUp/Dn: Select Array Enter: Display Array Esc: DoneUp/Dn: Select Array Enter: Delete Array Esc: DoneArray #%1 Arrays configuredChannel %1Main MenuOperation disallowed. Array Member is UP. May result in Data Loss.Up/Dn: Select Array Enter: Redefine Array Esc: DoneUp/Dn: Select Array Enter: Initialize Array Esc: DoneArray Size(MB) = %1Boot Array = NoData Block Size(KB) = %1This array is not the proper RAID level for this function.Array Status = OnlineArray Status = OfflineReboot the system using Ctrl+Alt+Del KeysThis array may have valid Data. Continue with Formatting.(Y/N)If you want to still continue, choose the Yes option.Up/Dn: Move Up/Down Enter: Select Drive Esc : Previous MenuArray cannot be Initialized. Some members of Array are not found.Spare #%1Member #%1Replacement Drive too smallDrive may have valid Operating System Partitions.This Drive has valid Partition Table. Continue(Y/N). Some Arrays have changed Configurations. Accept (Y/N). Be Sure to check the new array configuration before accepting it. Arrays Members have moved from original location. Before exiting ARCONFIG be sure to take a look at the new configurations.Invalid entry.Maximum number of arrays already configured.^Add an Array  Incomplete Arrays Found. Before exiting ARCONFIG be sure to use Replace Array Member or Delete Array Functions to fix these problems.Used to add an array. Maximum allowable array count is 4.^Delete an Array Deletes the specified array from your system.Unable to access drive #%1.Configuration for Array #%1UninitializedMember SCSI ID Channel Status CapacitySpare%1Failed to respondMarked DOWN Reconstruct Needed Replacement Needed DOWN  UP %1MBGBSideMirrorPrimarySecondary#%1The SCSI Read Capacity command for spare #%1 failed.Unknown error #%1 occurred.Writing Zeroes to Array is ...%1 complete.I/O error occurred while processing Adaptec command #%1.Tab: Select channel Up/Dn: Select drive Ins: Install drive Del: Deselect driveSpares are extra drives that are dedicated to this array to be automatically used if a drive fails.Do you want to define spares for array #%1? (y|n) Each array may have up to %1 spares.Maximum allowable spare count is %1.SPARE #%1 System Configured to Boot off Single Drive.Array # = %1Copy NetWare Drivers in %1 Directory? (y|n) Choose No option to specify your own pathDo you want to boot off an Array? (y|n) If you want to boot off a Single Drive, select the No option.Change Array ^Configuration Takes few minutes to several hours, depending on hard disk type.^Redefine an Array Used to redefine the drives in an existing array.This Drive has a valid partition table.If you do not want to use this drive, choose No optionAdd ^Spare Drive(s) This array already has the maximum number of spares.This function is used to add a spare to an existing array.DriveAre you sure that you want to delete this array. (y/n) :If you delete this array, all information on this array will be lost.SizeManufacturerChnIDTypeDrivesCreatedVerifiedReconstructed Array # Member SCSI ID Channel Status Bus #%1#%1 %2 %3SCSI IDs on Channel #%1 %2 %3Array #%1 Array #%1 Initialized on PCI Bus #%1 #%1%2 %3 %4Bus #=%1 Channel=%2 SCSI ID=%3^Redefine an Array Array #%1,Spare #%2Init MenuArray is initialized with all Zeroes. This Initialization method is faster than low-level formatting.Low-Level ^Format an Array Each drive in the array will be sent a SCSI Format command. This should be used only if the drives in the array REQUIRE a SCSI Format command.Improper drive count for this type of array.Initialize to RAID^5 ^Initialize an Array Initialize to RAID5 C^VT Initialize to RAID0 ^CVT Initialize to RAID^0 Mirrored arrays must consist of an even number of members.Initialize to ^Mirrored Are you sure? (y|n)Unable to access drive #%1. Array #%1 deleted.Member of Array #%1 replaced.Array #%1 marked bootable.Initialization of Array #%1 is complete.Low-level formatting of array #%1 is complete.Formatting Array #%1. Writing system sectors... Writing reserved sectors... CD-ROM Drivers copied. Update config.sys to include CD-ROM Drivers.Array Model = %1NetWare Drivers installed. Update startup.ncf to include NetWare Drivers.%1Put the Drivers diskette in floppy drive a:SCSI IO Error. Check the SCSI Configuration and run arconfig again.Are you sure you want to delete array #%1? (y|n) Use Up/Down Arrow keys to select drive; Enter to execute; Esc to quit.The Format command failed on drive #%1.Elapsed time %1Initializing all blocks on array #%1 to zero ... %2 complete.A SCSI Inquiry command failed.Product(%1) Page(0x%2) A SCSI Mode Sense command to a drive in the disk array has failed.The Read Capacity command for drive #%1 failed.A SCSI Mode Select command to a drive in the disk array failed.Offset(%1) Val(0x%2) Accept default or refer to the array user's manual for further details.Do you want to specify a new data block size? (y|n) %1KB 16 KB Cannot open %1. %1 WARNINGDelete ArrayArray #^1Array #^2Array #^3Array #^4Select UnitUnit #%1 Up/Dn: Move Up/Down Enter: Select Unit Esc : Previous MenuInitialize ^Logical Arrays Format Logical ^Arrays Select ArrayArray StatusArray State = Array Substate = UNKNOWNNumber of members = %1Spare drive %1 status = UPmarked DOWN Adaptec disk array #%d has DOWN drive(s). Member %1 status =  %1 %2 %3 %4  %1 %2 %3 %4 DOWNSelect Array TypeDOS Menu^Low-Level Format Initialize Array to ^Zero RAID^0 RAID0 ^CVT ^Mirrored RAID^5 RAID5 C^VT Select Initialize ModeArray %1All data on this array will be lost! Do you want to continue? (y|n) Creation date = %1F1 = Help toggle Arrow Keys or Hot Key = Select menu item Esc = Quit menuInvalid drive count for array type chosen.System MenuThe data block size for fault-tolerant arrays is the stripe size of both data and parity blocks. The data block size for RAID0 arrays is the stripe size of the data block.Invalid Adaptec disk array model number of %1 for command %2.Not enough drives to configure any RAID level.AHA-3980 Two Channel RAIDAthenaViking IIOff-lineOperational with DOWN member(s).Next DOWN member puts array off-line. Adaptec Disk Array Installation UtilityConfiguration MenuDo you want to allow this array to be converted to and from RAID0_CVT for specific applications? (y|n) Do you want to allow this array to be converted to and from RAID5_CVT for specific applications? (y|n) Type=Drive Channel IDSpare Channel IDArray #%1=%2 Inquiry command failed.Read Capacity command failed.Array #%1,Member #%2Tab: Select channel Up/Dn: Select driveDisplay Host ^Adapter DrivesTab: Select Channel Esc: DoneConfiguration change implemented.Adaptec disk array configuration changed.Conversion to RAID0_CVT is useful for expediting massive data transfers to the array, such as restoring an array from tape backup. After transferring the data, you can convert the array back to the safer RAID5 CVT type. Conversion to RAID0_CVT is useful for expediting massive data transfers to the array, such as restoring an array from tape backup. After transferring the data, you can convert the array back to the safer RAID5 CVT type. AHA-3985 Three Channel RAID%s Bus #%dRAID Boards