Copyright 1993-1998 Intergraph Corporation
All Rights Reserved

Including software, file formats, and audio-visual displays;
may only used pursuant to applicable software license agreement;
contains confidential and proprietary information of Intergraph
and/or third parties which is protected by copyright and trade
secret law and may not be provided or otherwise made available
without proper authorization.

RESTRICTED RIGHTS LEGENDS

Use, duplication, or disclosure by the U.S. Government is subject to
restrictions as set forth in subparagraph (c) (1) (ii) of the Rights
in Technical Data and Computer Software clause at DFARS 252.227-7013
or subparagraphs (c) (1) and (2) of Commercial Computer Software --
Restricted Rights at 48 CFR 52.227-19, as applicable.

Unpublished -- rights reserved under the Copyright Laws of the
United States.

Intergraph Corporation
Huntsville, Alabama   35894-0001

-------------------
Version Information
-------------------------------------------------------------------------------
Product:        SPECMAN        IACS Specification Manager
Number:        SJBY084AA-0600A
Version:        06.00.02.00
Date:             29-APR-1998
Description:    This product provides the capability for a
	        Database Administrator (DBA) to customize
	        a relational database schema to the unique
	        individual needs and environment of its
	        users.
-------------------------------------------------------------------------------
End of Version Information
--------------------------


-----------------
Installation Help
-----------------


------------------------ 
End of Installation Help 
------------------------ 

---------------
Getting Started
---------------


----------------------
End of Getting Started
----------------------


-------------
Documentation
-------------


--------------------
End of Documentation
--------------------


--------
Training
--------


---------------
End of Training
---------------


----------------
Product Sections
----------------

	Not Applicable to this version.

-----------------------
End of Product Sections
-----------------------


-----------
API Changes
-----------


------------------
End of API Changes
------------------


---------
New Fixes
---------

-------------------------------------------------------------------------------

TR #:319702497  C          Date Filed : 10/07/1997    Product Name : IACSSPEC
0NT     4 A CLOSED  -  FIXED                     P-3 06.00.00.00 06.00.01.01
Desc. : System Check Report:
          Will not run if IA_HOME is not defined.  Gives no message or error,
          just disappears without a clue.
          Reported by Cindy and experienced by Melinda...
          10/7/97
Notes : Fixed by Carl.  Added additional error notifications and improved
          some of the existing ones.  4/9/98
          Fixed verified by Stafford Jackson.                                  

-------------------------------------------------------------------------------

----------------
End of New Fixes
----------------


------------
New Features
------------

The SpecPrint processor should now be used to print database specifications.
Move the "InitFiles\*.dot" files to "Winword\template" prior to the first run
of SpecPrint.

The AIS Administrator processor can only be run by a user who has an entry 
in the sm_user database table.

-------------------
End of New Features
-------------------


-------------
Open Problems
-------------

-------------------------------------------------------------------------------

TR #:319800454  C          Date Filed : 03/06/1998    Product Name : IACSSPEC
0NT     1 A OPEN - FILED                         P-4 06.00.00.00 06.00.00.00
Desc. : Default Database:
          Airport Communication Frequency, Airport Radio and Navaid Radio
          contain invalid combinations of parent ('H' and 'S') type relation-
          ships.

-------------------------------------------------------------------------------

TR #:319800453  C          Date Filed : 03/06/1998    Product Name : IACSSPEC
0NT     1 A OPEN - FILED                         P-4 06.00.00.04 06.00.00.04
Desc. : SpecMan:
          Should not allow Hierarchical and Multi-Parent relations on the
          same feature.  This situation exists now in the Airport Communication
          Frequency feature in the default database.
          MTM 3/6/98

-------------------------------------------------------------------------------

TR #:319800413  C          Date Filed : 03/02/1998    Product Name : IACSSPEC
0NT     1 A OPEN - FILED                         P-4 06.00.00.06 06.00.00.06
Desc. : SpecMan:
          The system allows you to modify the attribute field 'Graphic
          Attribute' (database column - in_graphics) from Publishing, Charting,
          or Both to None without verifying that the attribute is not used in
          Extraction or Symbolization rules.  If this attribute is used in a
          rule, problems may  occur in the Rules, Extraction and Symbolization
          processors if it is modified without first being removed from the rules.
          MTM 3/2/98

-------------------------------------------------------------------------------

TR #:319800385  C          Date Filed : 02/26/1998    Product Name : IACSSPEC
0NT     1 A OPEN - FILED                         P-4 06.00.00.04 06.00.00.04
Desc. : Default Database:
          The default database does not contain an entry in the sm_processor
          table for specprint.  UpdateDB creates this entry but when you try
          to run updatedb against an initial load of the default database, it
          says the database is up-to-date and doesn't execute.  (Remove the
          sm_general table an it will run.)
          MTM                                                                  

-------------------------------------------------------------------------------

TR #:319800348  C          Date Filed : 02/24/1998    Product Name : IACSSPEC
0NT     1 B OPEN - REVIEWED                      P-3 06.00.00.00 00.00.00.00
Desc. : Update DB did not do a sucessfully update run on a Navcan database
          installed on grumpy3 node.  The schema name is "cindy".  The process
          error states "During the loading of relation specifications for the
          system table the file \ss_sm_relations.txt could not be open."
Notes : Update DB runs successfully when the envir variable
          IA_INITFILES_PATH is defined is the iacsrc file.  Lowered priority
          with plans to include note in README for 2/27 delivery.  Need to
          redeliver ENVIR with new variable and update documentation in order
          to close this TR.
          MTM 2/26/98
          Envir has been re-delivered with the fix.
          Documents and help files updated.  CR 3-16-98
          Need error message that tells user to set the resource variable - jcp

-------------------------------------------------------------------------------

TR #:319702907  C          Date Filed : 12/19/1997    Product Name : IACSSPEC
0NT     1 B OPEN - REVIEWED                      P-4 06.00.00.00 06.00.00.05
Desc. : SpecMan:
          On the Attribute Code List window, the Maximum Value Length field is
          supposed to limit the number of characters you can enter in the Value
          field, but it does not.
          Reported by Cathy Rupp.  12/19/97
          (MTM)
Notes : Duplicate of TR 319700907.  MTM 1/98
          This TR status has been modified to "open reviewed" becuase the problem
          still exists in 06.00.00.05 version of SPECMAN. The duplicate TR
          319700907 has been closed by Stafford Jackson.                       

-------------------------------------------------------------------------------

TR #:319702588  E          Date Filed : 10/23/1997    Product Name : IACSSPEC
NT     1 K OPEN - SCHEDULE DEFERRED             P-4 06.00.00.00 06.00.00.00
Desc. : NRCan (Cindy Doyle)  worksheet 7931043
          Specman
          Specman needs to check for the RDBMS reserved words before adding
          or modifying attribute names.
Notes : Not feasible fix at this time.  MTM 1/98

-------------------------------------------------------------------------------

TR #:319702551  C          Date Filed : 10/14/1997    Product Name : IACSSPEC
0NT     1 A OPEN - FILED                         P-4 06.00.00.00 06.00.00.00
Desc. : SpecMan: Reported by Cindy Doyle.
          The High-Low value valid ranges are not updated when defining a
          Float or an Integer attribute type.  The High value should be changed
          automatically for the highest value supported by the system.

-------------------------------------------------------------------------------

TR #:319702550  C          Date Filed : 10/14/1997    Product Name : IACSSPEC
0NT     1 A OPEN - FILED                         P-4 06.00.00.00 06.00.00.00
Desc. : SpecMan: Reported by Cindy Doyle.
          When adding a logical attribute, if the "Required-Not Null" check box
          is not hit, the system drops all entered data so, the user has to
          re-type the whole information in the attribute form to complete the
          operation.  The system should simply let the user click on the
          "Required - Not Null" check box when forgotten.  Also, the error
          message does not mention clearly that a logical attribute is required
          to be NOT NULLABLE.                                                  

-------------------------------------------------------------------------------

TR #:319702542  C          Date Filed : 10/14/1997    Product Name : IACSSPEC
0NT     1 A OPEN - FILED                         P-4 06.00.00.00 06.00.00.00
Desc. : SpecMan: Reported by Cindy Doyle.
          The following sequence of operations cause a system crash:
          - Open feature information form.
          - Query DB
          - Open Feature definition form
          - Click in the text box of the Feature Definition form
          - Click outside the Feature definition form.

-------------------------------------------------------------------------------

TR #:319702501  C          Date Filed : 10/08/1997    Product Name : IACSSPEC
0NT     1 A OPEN - FILED                         P-4 06.00.00.00 06.00.00.00
Desc. : SpecMan:
          The field relation in the date of last modification box is not
          updated when creating a new attribute rule (relationship).  It is not
          obvious in the documentation that an attribute relationship is an
          attribute rule.  The terminology should be changed to prevent con-
          fusion with feature relationships.
          Reported by Cindy Doyle.

-------------------------------------------------------------------------------

TR #:319702202  C          Date Filed : 08/08/1997    Product Name : IACSSPEC
0NT     1 A OPEN - FILED                         P-3 06.00.00.00 06.00.00.00
Desc. : SpecMan:
          If you create a feature and define relationships for that feature
          then delete the feature before building the table, the relationship
          information is left in the sm_relations table.  This causes problems
          for RDBC and other processors because there are relationship
          definitions that point to features that do not exist.  (If you build
          the table, you have to drop the table before deleting the feature.
          The drop table function test for relationships and forces the user
          to remove these before dropping the table.)
          MTM - NavCanada Training - 8/97                                      

-------------------------------------------------------------------------------

TR #:319701962  C          Date Filed : 07/15/1997    Product Name : IACSSPEC
0NT     1 A OPEN - FILED                         P-4 06.00.00.00 06.00.00.00
Desc. : Authorize Users:
          Query for 'Disabled Users' returns none even though they exist in the
          database.  A full query will include the 'Disabled User'.  A query
          based on another user mode such as 'Ais Administrator' does return
          a correct sub-set of users.
          MTM 7/15/97

-------------------------------------------------------------------------------

TR #:319701960  C          Date Filed : 07/15/1997    Product Name : IACSSPEC
0NT     1 A OPEN - FILED                         P-4 06.00.00.00 06.00.00.00
Desc. : Default Database - Font library:
          We are still delivering fontlib.  I think we need to deliver
          font.rsc to be compatible with MicroStation 5.0.
          MTM  7/15/97                                                         

-------------------------------------------------------------------------------

TR #:319701923  C          Date Filed : 07/10/1997    Product Name : IACSSPEC
0NT     1 A OPEN - FILED                         P-4 06.00.00.00 06.00.00.00
Desc. : AISADMIN:
          When I loaded the IACS software on the demo machine, I used
          the E: partition.  Aisadmin would not run.  Received errors - "Could
          not open message file [ai_mon.msg], [ai_mon2.msg]"; "c:\libosch\src\
          oschema.c Could not evaluate message key 0x..."; "UMS files are not
          properly initilized...."  My .iacsrc path variables were defined
          correctly for the E: partition and all the other IACS products were
          running correctly.  I had to load AisAdmin to C: (without removing it
          from E:) to get it to run.  Maybe there is something in AISAdmin
          that is looking specifically at C: partition?
          MTM 7-10-97.                                                         

-------------------------------------------------------------------------------

TR #:319700947  D          Date Filed : 03/26/1997    Product Name : IACSSPEC
0NT     1 B OPEN - REVIEWED                      P-3 06.00.00.00 00.00.00.00
Desc. : FEAMAN
          Feature: Cruise Table -- Application Error on Add Record.
          On the Cruise Table feature window, select Add Record, select a
          valid Source Name from the list, and press Return.
          Key in the following values:
          Cruise Table Ident: HIP
          Sequence Number: 10
          Select Apply, and an Application Error occurs.
          [las]
Notes : This problem was transfered from a problem in Feaman to a problem in
          IACS default deliverable database.   -slj

-------------------------------------------------------------------------------

TR #:319700928  D          Date Filed : 03/25/1997    Product Name : IACSSPEC
0NT     1 D OPEN - FIXED REJECTED                P-3 06.00.00.00 00.00.00.00
Desc. : [FEAMAN/SM_CHKRP/AERODB]
          In FeaMan, beginning on the Select Feature window, if the Airport
          Radio Frequency or Airport Radio Notes features are selected,
          and Apply is selected, the result is first an Error Box with the
          message: "Unable to prepare select statement. See RIS Error.",
          followed by an Application Error.
          This error occurs because the aptradfreq and aptradio_n tables are
          not correct in the aerodb.dmp file (default data base). The number
          of columns in the sm_attr and ris5columns tables is not the same
          after aerodbld. Also, the sm_chkrp tool failed to find this problem.
          Finally, though the data base was incorrect, FeaMan should not
          fail with an Application Error, but should report the error and
          either continue processing or exit gracefully.
          [las]

-------------------------------------------------------------------------------

TR #:319700916  D          Date Filed : 03/21/1997    Product Name : IACSSPEC
0NT     1 A OPEN - FILED                         P-3 06.00.00.00 06.00.00.00
Desc. : SPECMAN
          The Specman:Format Definition window Sample Data keyin field
          appears to be ignored when an Existing Format exists for the data
          type. If an Existing Format is tested, the following command
          sequence seems to be correct: Select the desired Existing Format
          in the Existing Format field, select Test Format. As an example,
          use the "G-Double Precision Fltg Pt" Attribute Type (commonly used
          for latitude/longitude attributes). Note that even if a new format
          is keyed into the Format Specifiers field, the software appears
          to use the sm_format.fmt_example value rather than the value
          keyed into the Sample field.
          [las]

-------------------------------------------------------------------------------

TR #:319700915  D          Date Filed : 03/21/1997    Product Name : IACSSPEC
0NT     1 K OPEN - SCHEDULE DEFERRED             P-4 06.00.00.00 00.00.00.00
Desc. : SPECMAN
          On the Specman:Format Definition, some buttons and fields are
          initially enabled that should not be.
          The Existing Formats MCF, even if blank, may be selected, which
          in turn enables the Delete Format button.
          The Test Format and Apply buttons are also initially enabled,
          and should not be.
          [las]

-------------------------------------------------------------------------------

TR #:319700913  D          Date Filed : 03/21/1997    Product Name : IACSSPEC
0NT     1 K OPEN - SCHEDULE DEFERRED             P-4 06.00.00.00 00.00.00.00
Desc. : SPECMAN
          When the Sequence/Window Position window is first displayed, no
          attribute is selected in the Attribute List. The Sequence Number
          and Window Position keyin fields are editable, but should not be
          edited until an attribute is selected from the list. If edited, the
          attribute actually changed is the first one in the list.
          [las]

-------------------------------------------------------------------------------

TR #:319700912  D          Date Filed : 03/21/1997    Product Name : IACSSPEC
0NT     1 K OPEN - SCHEDULE DEFERRED             P-4 06.00.00.00 00.00.00.00
Desc. : SPECMAN
          On the Sequence/Window Position window, both the Sequence Number
          and Window Position fields appear to be editable. However, the only
          one actually editable is determined by the position of the
          Order Mode toggle. Any attempt to change the inactive field looks
          like it worked; that is, the operator may edit it and select Apply,
          no errors are logged, all appears ok, but the change is not made.
          If the Order Mode toggle is set to Sequence, then the
          Sequence Number keyin field is the only one actually editable;
          if the Order Mode toggle is set to Window Position, then the
          Window position keyin field is the only one actually editable.
          [las]

-------------------------------------------------------------------------------

TR #:319700911  D          Date Filed : 03/21/1997    Product Name : IACSSPEC
0NT     1 K OPEN - SCHEDULE DEFERRED             P-4 06.00.00.00 00.00.00.00
Desc. : SPECMAN
          Able to attempt invalid operation:
          On the Attribute Definition window, the operator may attempt to
          Attach Link Def to a non-existent attribute.
          For example, select Attach Link Def, then AGA3 Heliport Temp, then
          the top of the blank Linked Attribute Name MCF, then select Apply.
          Message states "Update of attribute definition record is
          complete". Actually, nothing happened.
          [las]

-------------------------------------------------------------------------------

TR #:319700910  I          Date Filed : 03/21/1997    Product Name : IACSSPEC
0NT     1 D OPEN - FIXED REJECTED                P-4 06.00.00.00 00.00.00.00
Desc. : SPECMAN
          On the Specman:Attribute Definition window, the Current Feature Name,
          Current Attribute Name, and Current Definition Text fields
          "fall off" the right side of the window.
Notes : Fixed. [cag 7/18/97]                                                 

-------------------------------------------------------------------------------

TR #:319700906  I          Date Filed : 03/21/1997    Product Name : IACSSPEC
0NT     1 A OPEN - FILED                         P-3 06.00.00.00 06.00.00.00
Desc. : SPECMAN
          Code List - Description Page
          Modified the first code list to have 64 characters in each of the
          five Description Pages. Added another code list. When moving to
          Description Pages 2 - 5, the first description is also displayed in
          the last code value's description. After adding another in the
          middle of the list, noted that it inherited the same problem.
          [las]                                                                

-------------------------------------------------------------------------------

TR #:319700901  I          Date Filed : 03/21/1997    Product Name : IACSSPEC
0NT     1 A OPEN - FILED                         P-3 06.00.00.00 06.00.00.00
Desc. : SPECMAN
          Code List window problems:
          1) After Query is selected, an associated list icon appears at the
          end of the Code List Description field. This list is always blank.
          2) Entirely blank code lists can be added.
          3) The Code List Description cannot be modified, even though that is
          where your cursor is placed when Modify Code List is selected,
          UNLESS the Code List is attached with the Attach Code List button.
          If it is NOT attached, and the operator modifies it and selects
          Apply, a message is received: "No code list attached to this
          attribute name", and no change is made.
          4) The Code List value field allows input of more than 20
          characters. The entry is truncated to 20 characters when Apply
          is selected. Also, the Code List Description field allows input
          of more than 64 characters. The entry is truncated to 64 characters
          when Apply is selected. No warning or error messages received.
          5) Able to select Modify Code List and Apply; message states "Code
          list modified", though is wasn't. Also true for Modify button under
          row editing.
          6) A Code List query returns a query set that seems to have no
          order. For consistency's sake, it would be correct to order the
          list by Code List Description (sm_code.code_desc).
          [las]                                                                

-------------------------------------------------------------------------------

TR #:319700899  I          Date Filed : 03/21/1997    Product Name : IACSSPEC
0NT     1 A OPEN - FILED                         P-4 06.00.00.00 06.00.00.00
Desc. : SPECMAN
          User Interface problems related to the Attribute Information window:
          1) The Attribute Info button (on the Feature Information window)
          does not pop up when the Attribute Information window is dismissed.
          2) Able to select Modify Attribute, and Apply, without ever really
          modifying anything, and the message states: "Attribute modified".
          3) Able to delete or modify an attribute that is already marked for
          delete.
          [las]

-------------------------------------------------------------------------------

TR #:319700897  I          Date Filed : 03/21/1997    Product Name : IACSSPEC
0NT     1 A OPEN - FILED                         P-3 06.00.00.00 06.00.00.00
Desc. : SPECMAN
          When a single quote is entered in a character field, and the field
          is processed by RIS, a RIS Error results.
          [las]

-------------------------------------------------------------------------------

TR #:319700894  I          Date Filed : 03/21/1997    Product Name : IACSSPEC
0NT     1 K OPEN - SCHEDULE DEFERRED             P-4 06.00.00.00 00.00.00.00
Desc. : SPECMAN
          User Interface problems--
          1) All windows are always active, but the only valid actions are on
          the most recently brought up window. Returning to a previous window
          by a means other than exiting the sub-window(s) can lead to
          unpredicatable results. For example, if the Feature Information
          window has just been brought up, the operator should not be allowed
          to return to the Main window without first exiting the Feature
          Information window.
          2) The Apply gadget is always active when a form is first entered,
          even though no valid Apply action exists. This allows the operator
          to select the Apply button, with unknown results.
          --In both of these cases, the point is to prevent  the operator
          from performing invalid operations.
          [las]

Notes : Would require total rework of SPECMAN forms (MM/CP - 9/8/97).        

-------------------------------------------------------------------------------


TR #:319700477  C          Date Filed : 02/05/1997    Product Name : IACSSPEC
0NT     1 A OPEN - FILED                         P-3 06.00.00.00 06.00.00.00
Desc. : SM_CHECK_RP
          sm_check_report needs to validate attribute class against what is
          defined in the sm_relations table.  Some attributes in the default
          database are not set correctly. [cag]
          Need to update default database.   Check SpecMan to verify that this
          situation can not be created by SpecMan.  Updatedb may need to
          include a 'fix' for current customer's databases.  MTM 9/9/97        

-------------------------------------------------------------------------------
--------------------
End of Open Problems
--------------------