              READPC.TXT - R13c4 PC-Specific Information
     +==========================================================+
                                   
                           18 December 1995



This file contains installation, driver, and networking information
for PC platforms (Windows, Windows 95, Windows NT, and DOS).

=====================================================================-
CONTENTS
========-

  - The AutoCAD Installation
  - Windows-Specific Information
  - DOS-Specific Information
  - Platform Independent Driver Information
  - Windows-Specific Driver Information
  - DOS-Specific Drivers
  - Network and Hardware Lock Information for PCs
  - Windows-Specific Network Information
  - DOS-Specific Network and Hardware Lock Information

The following list describes the R13c4 readme files:

README         Contains general information related to all platforms.
READPC         Contains DOS-specific and Windows-specific information.
READDOC        Contains documentation updates and revisions.
READDEV        Describes the text files that explain how to compile,
               link, and debug ADS and ARX applications, and tells
               where to find them.
READHIST       Describes the history of enhancements, fixes, and
               information related to each of the R13 update releases.




=====================================================================-
THE AUTOCAD INSTALLATION
========================-

  - Driver Files Path Name Length
  - Uninstalling AutoCAD
  - Not Enough Disk Space Message -- Installer Update Option


Driver Files Path Name Length
=============================-
If at all possible, choose the default path name for the location to
install AutoCAD. If this is not convenient, make sure that the path to
the AutoCAD files is such that the drivers have a path name that is
safely less than 90 characters.

Assuming ACAD is installed in $ACADHOME and the drivers are in the
default file path $ACADHOME/DRV, then any driver
$ACADHOME/DRV/DRIVER.DLL must have a file path (including drive
letter) that is less than 90 characters.


Uninstalling AutoCAD
====================-
If you have installed both R13 DOS and Windows and are taking
advantage of the common (/COM) directory structure you should not use
the Windows Uninstall feature.  The Windows Uninstaller removes the
shared files in the /COM directory tree used by both AutoCAD for  DOS
and AutoCAD for Windows. These files are needed by AutoCAD for DOS.
To manually remove the Windows application, delete the /WIN directory
tree and remove the program icons.


Not Enough Disk Space Message -- Installer Update Option
========================================================-
If you choose the Update option, you may get a message about not
having enough disk space. The installer is checking for a full
install, not an update over an existing installation.  If you know
that you have enough disk space, choose OK to continue. The update is
usually only a few additional MB's.


=====================================================================-
WINDOWS-SPECIFIC INFORMATION
============================-


  - Using DXFIX with Norton Desktop on Windows 3.1
  - Long File Names on NT
  - OLE 2.0 Limits in AutoCAD
  - Using ADS and ARX Applications
  - DELL Computer Systems and Electronic Document Display Problems
  - Norton Desktop Problems with AutoCAD Dialog Boxes
  - COMPAQ DeskPro XL 566 Users
  - COMPAQ Qvision 1024/E Users
  - Clipboard Issues
  - Lack of Response from 16-bit OLE 2.0 Applications
  - AutoCAD Sessions
  - Updated Shaft Application
  - Text and Font issues

Using DXFIX with Norton Desktop on Windows 3.1
==============================================-
Norton Desktop has compatibility problems with the DXFIX utility. If
you use Norton Desktop, you should use the DXFIXND.EXE program in
place of DXFIX.EXE.


Long File Names on NT
=====================-
The SHELL command issues an error at the command line following an
attempt to call an executable with embedded spaces in it's file name.


OLE 2.0 Limits in AutoCAD
=========================-
+   Text that is Dragged and Dropped into AutoCAD from Word 7
    initially displays as a properly sized image. If that text is
    edited, the update causes the text to become very small and the
    size to be changed to a "Full Page" picture. This appears to be a
    problem with Word 7. One possible workaround is to use WordPad
    instead of Word.

+   Create from file brings AutoCAD up in a dormant state in the
    background. When starting as an OLE server, the AutoCAD screen
    does not appear. However, if the Aerial viewer or floating
    toolbars are enabled, then they will be the only thing visible.
    When inserting an AutoCAD drawing via "Create from File" and
    Aerial Viewer or floating toolbars turned on, expect to see ONLY
    the Aerial Viewer and floating toolbars, and NOT AutoCAD.

+   Objects from AutoCAD Pasted into Excel 7.0 come in as a blank,
    and only after Updating Links does the actual object show.

+   OLE objects during Pan&Zoom of a Plot Preview may sometimes be
    drawn in the wrong places. This does NOT affect the final output.

+   If AutoCAD is not running when you insert an AutoCAD object into
    Borland's Quattro Pro, Quattro Pro does not correctly start
    AutoCAD. Quattro Pro appears to time out before AutoCAD starts as
    a server. However, if you click OK and repeat the operation,
    AutoCAD starts and the operation succeeds.


Using ADS and ARX Applications
==============================-
The following problems are attributed to the use of SHARE.EXE:

+   ADS and ARX applications may fail to execute properly
+   ADS and ARX applications may fail to unload
+   The AutoLISP findfile function may not work correctly

To maintain file protection in a multi-user environment, use
VSHARE.386 instead of SHARE. You have three options, each explained in
greater detail below:

+   Use VSHARE.386 instead of SHARE.EXE
+   Continue to use SHARE.EXE
+   Use neither SHARE.EXE nor VSHARE.386

VSHARE comes with newer Microsoft Windows products such as Office,
Word, Windows for Workgroups, etc. VSHARE is a total replacement for
SHARE.EXE, so you don't need both. Take SHARE.EXE out of your
AUTOEXEC.BAT, and add the following line to the [386Enh] section of
your SYSTEM.INI file:

      device=vshare.386.

Continuing to use SHARE is not a problem assuming that you don't care
about being able to unload ADS or ARX applications. If you try to
unload an application with SHARE loaded, the unload fails cleanly with
a command line notice of the failure to unload -- AutoCAD continues on
without a problem.

It is also possible to run AutoCAD without loading SHARE or VSHARE.
Doing so will allow you to unload ADS and ARX applications but does
have the following consequences:

+   You are unable to use ASE and ADE without SHARE or VSHARE
+   Many Microsoft programs require SHARE or VSHARE to be loaded
+   File protection in a multi-user environment is compromised


DELL Computer Systems and Electronic Document Display Problems
===============================================================-
On certain DELL OPTIPLEX 466/L systems with a Tseng video adapter and
on the DELL ET 4000 version 1.11 VESA display driver, text might be
"blacked-out" (highlighted in black). This results in certain portions
of text from the electronic version of the AutoCAD documentation to be
unreadable.


Norton Desktop Problems with AutoCAD Dialog Boxes
=================================================-
When you have the Norton Desktop for Windows loaded, you might
encounter some difficulties with AutoCAD's file dialog boxes. To
workaround any problems, press ESC to cancel the dialog box, and then
reenter the command.


COMPAQ DeskPro XL 566 Users
===========================-
Users of COMPAQ DeskPro XL 566's need to make sure that Windows is
configured to disable 32-bit disk access. Failure to do this can cause
problems in Window's virtual memory subsystem, which will prevent
Windows from running properly.

To disable 32-bit disk access, edit the [386Enh] section of Window's
SYSTEM.INI file, setting the 32BitDiskAccess flag off. For example:

      ;32-BIT ACCESS NEEDS TO BE TURNED OFF IN COMPAQ XL 5/66
      32BitDiskAccess=off

DeskPro XL 566 user's can also use the 386 Enhanced icon from the
Windows Control Panel to change the 32-bit disk access setting. See
the Microsoft Windows User's Guide for more information on changing
swap file settings.


COMPAQ Qvision 1024/E Users
===========================-
If you are using a Compaq Qvision 1024/E card with Windows 95, using
the video driver shipped with Windows 95, you will see pixels left
behind on the graphic screen from some "dragging" operations such as
stretch. WHIP driver users will also see pixels left behind from
cursor movement. The problem can be fixed by upgrading to the v1.11.7M
driver from Compaq, available from their Web site, Compuserve and
other on-line sources.


Clipboard Issues
================-
The Clipboard features for Release 13 don't gray out depending on data
in the Clipboard viewer. The features affected by this are Cut, Copy,
Copy View, Paste, Paste Special, Links, and Insert Object.


Lack of Response from 16-bit OLE 2.0 Applications
=================================================-
AutoCAD might not respond to OLE requests from 16-bit OLE 2.0
applications. For example, using Insert, Object, from Microsoft Word
for Windows 6.0 and selecting AutoCAD will result in a message that
the application can't be found. This is recognized as a known problem
with Windows and not necessarily an AutoCAD problem.


AutoCAD Sessions
================-
Only one session of AutoCAD can be run at a time on DOS, Windows 3.x..
Before you begin a new session of AutoCAD, please wait until any
previous session has exited completely.


Updated Shaft Application
=========================-
Release 13 includes an updated Shaft sample application, which
demonstrates a Dynamic Data Exchange (DDE) link between AutoCAD and
Microsoft Excel. The Shaft menu is now a partial menu that can be
inserted anywhere on the Windows menu bar. For more information on
this application, see the comments in the file shaft.mnu, which is
located in the Windows sample directory.


Text and Font issues
====================-


Default Mtext Editor Font
-------------------------
When you choose CANCEL in the Select Font dialog box for a font to be
used in the Mtext Editor, AutoCAD uses the Arial font as the default
font.


RTF Text and the Mtext Editor
-----------------------------
RTF text isn't recognized by the Mtext Editor. Text from other
programs with embedded formatting will lose formatting when Imported
or Pasted into the Mtext Editor.


PostScript and TrueType Font Mapping in acad.ini
------------------------------------------------
The acad.ini file assumes that AutoCAD's TrueType fonts are not
installed in Windows. If you do install AutoCAD's TrueType fonts (by
using the Control Panel), the following items in the [MTE Fonts]
section should be changed as follows:

    bgothl=BankGothic Lt BT;400;0
    bgothm=BankGothic Md BT;400;0
    compi=CommercialPi BT;400;0
    comsc=CommercialScript BT;400;0
    dutch=Dutch801 Rm BT;400;0
    dutchb=Dutch801 Rm BT;700;0
    dutchbi=Dutch801 Rm BT;700;1
    dutcheb=Dutch801 XBd BT;900;0
    dutchi=Dutch801 Rm BT;400;1
    monos=Monospace821 BT;400;0
    monosb=Monospace821 BT;700;0
    monosbi=Monospace821 BT;700;1
    monosi=Monospace821 BT;400;1
    stylu=Stylus BT;400;1
    swiss=Swis721 BT;400;0
    swissb=Swis721 Blk BT;;400;0
    swissbi=Swis721 Blk BT;400;1
    swissbo=Swis721 BdOul BT;400;0
    swissc=Swis721 Cn BT;400;0
    swisscb=Swis721 BlkCn BT;400;0
    swisscbi=Swis721 BlkCn BT;400;1
    swisscbo=Swis721 BdCnOul BT;400;0
    swissci=Swis721 Cn BT;400;1
    swissck=Swis721 BlkCn BT;400;0
    swisscki=Swis721 BlkCn BT;400;1
    swisscl=Swis721 LtCn BT;400;0
    swisscli=Swis721 LtCn BT;400;1
    swisse=Swis721 Ex BT;400;0
    swisseb=Swis721 Ex BT;700;0
    swissek=Swis721 BlkEx BT;400;0
    swissel=Swis721 LtEx BT;400;0
    swissi=Swis721 It BT;400;1
    swissk=Swis721 Blk BT;400;0
    swisski=Swis721 Blk BT;400;1
    swissko=Swis721 BlkOul BT;400;0
    swissl=Swis721 Lt BT;400;0
    swissli=Swis721 Lt BT;400;1
    umath=UniversalMath1 BT;400;0
    vinet=Vineta BT;400;0

The syntax of each of the above acad.ini entries is as follows:

    <name>=<face>;<weight>;<italic>

where:

name           is the AutoCAD font name
face           is the Windows typeface name
weight         1-1000 or 0 for default font weight
italic         0 for upright or 1 for slanted (Italic)


=====================================================================-
DOS-SPECIFIC INFORMATION
========================-

  - Using the Esc Key to Cancel
  - Vibrant Driver and Scripts
  - MTEXT and Memory
  - Importing a File with MTEXT and the Temporary File Name


Using the Esc Key to Cancel
===========================-
Pressing the [ESC] key should cancel the current command. If it
doesn't, use [CTRL]+[C] instead.


Vibrant Driver and Scripts
==========================-
You can't use scripts to configure this driver.


MTEXT and Memory
================-
If you run out of memory when MTEXT attempts to use the DOS editor,
configure your system so that you have more memory. You can put DOS in
high memory or use the SHROOM command before invoking AutoCAD. Consult
your DOS manual for instructions on how you do this.


Importing a File with MTEXT and the Temporary File Name
=======================================================-
When you import a file for MTEXT, load the file into the editor and
save it using the name AC000512. (the period or fullstop [.] after
"AC000512" is required). When you're prompted whether you want to
overwrite the existing file of the same name, choose Y (Yes).

The temporary file name AC000512. must exist when using MTEXT in a DOS
editor. If you attempt to rename the temporary file to a name other
than AC000512., the MTEXT operation will be canceled.


=====================================================================-
PLATFORM INDEPENDENT DRIVER INFORMATION
=======================================-

  - Digitizer Drivers
  - HP-GL/2 Plotters
  - Plotter Drivers


Digitizer Drivers
=================-


SKETCH Command with ORTHO ON
----------------------------
Using the SKETCH command with ORTHO turned on and a projective tablet
calibration produces unusual results. It is recommended that you turn
ORTHO OFF when SKETCHing.


Numbers Chosen from Digitizer Template
--------------------------------------
After picking any number (angle, etc.) from the digitizer template,
dialog boxes act as if FILEDIA was temporarily set to 0 (they don't
come up). Internally, AutoCAD is expecting the next input to be from
the template and so it suppresses dialog boxes.


Digitizers and Monitor Interference
-----------------------------------
Putting your digitizer close to, or on top of, the monitor may cause
the cross-hairs to oscillate due to electromagnetic interference. If
you see this behavior, try relocating the digitizer.


Screen Saver Interaction
------------------------
AutoCAD R13 digitizers will not interrupt an active screen saver. To
deactivate the screen saver, move the mouse or depress a key on the
keyboard. The backspace key works well.


HP-GL/2 Plotters
================-


HPRENDER
--------
If you are using an HP-GL/2 plotting device, and have configured
AutoCAD for rendering, you can use HPRENDER to configure the render
attributes and send the rendered drawings to an HP-GL/2 plotter.
Use the following procedure to configure for rendering.
1. At the command prompt, enter HPRENDER.
2. In the Render Configuration dialog box, verify that the .cfg file
    displayed at the top is the same as the current one displayed in
    RCONFIG.  If not, use RCONFIG to change the .cfg file.
3. Set the render attributes.
    Render Type
     - Smooth  = smooth ON
     - Facet  = smooth OFF

    Media Size
     - Click on either inches or millimeters then specify the width
    and height of the media to be used in the plotter for rendered
    output.  The size you specify is used as the default in HPMPLOT.

    Position of Rendered Plot on Media
     - Specify the bottom-left and top-right corners of the image to
    be rendered.

    Render to File
     - To send the rendered output to a file rather than to a
    plotter.  Specify the filename in the window that appears.

4. To send the rendered drawing to the plotter, click on OK.


HPMPLOT
-------
To plot a drawing with only one viewport rendered, and the other
viewports not rendered, use HPMPLOT. The "M" in HPMPLOT stands for
mixed plot. After using RCONFIG to configure AutoCAD for rendering,
use the following procedure to render one viewport with HPMPLOT.
1.  At the command prompt, enter HPMPLOT.
2.  In the Mixed Plot Configuration dialog box, verify that the
    plotter displayed at the top is the same as the one whose .cfg
    file is current in RCONFIG.  To change the current plotter, click
    on the Device and Default selection.
3.  Change the following mixed plot parameters as required.
    Media Size
     - Click on either inches or millimeters, then specify width and
    height of the media to be used in the plotter.  The default is as
    specified in HPRENDER.

    What to Plot
     - Choose whether the area to be plotted is:
          Display: as displayed on screen.
          Extents: as defined by the extents of the drawing.
          Limits: as defined by the LIMITS variable.

    Hide Lines
     - Select this option if you don't want hidden lines to be
    plotted.

    Render Type
     - Smooth = smooth ON
     - Facet = smooth OFF

    To File
     - To send the output to a file rather than to the plotter.
    Specify the filename in the window that appears.

    Scale
     - To plot the drawing to the same scale as specified in the
    drawing, keep the default display of 1 to 1.  To plot to an
    enlarged scale, make the Plotted Units greater than the Drawing
    Units.  If you want the drawing to be scaled to fit the media
    size you specified earlier, choose Plot to Fit.

    Viewport to Render
     - Click on Select , then choose the relevant viewport in
    AutoCAD.
4.  To send the drawing to the plotter, click on OK.


Plotter Drivers
===============-


Default Plot Rotation and Offset
--------------------------------
Release 13 redefines the default meaning of plot rotation and offset.
Many plots produced with R13 using R12 plot rotation and offset
parameters will not produce the same results under R13 as they did
under R12.

Chapter 10, "Layout and Plotting," in the AutoCAD User's Guide
contains a detailed discussion of the new plot rotation and offset
mechanism.

If you want to revert to the R12 method of plot rotation and offset,
change the value of the SETVAR, PLOTROTMODE to 0. The default is 1,
which implements the new plot rotation and offset mechanism.


Operator call warning on Canon LBP-4
------------------------------------
When the Canon LBP-4 device is powered up, it loads the setting for
current paper size from its non-volatile RAM. This paper size setting
cannot be changed from the front panel of the device. Typically, the
initial paper size value will be A4 paper. To change this, the user
must run the Windows-based utility provided by Canon.

Since some AutoCAD users will not have access to Windows, AutoCAD will
now send down a command to change the current setting for the paper
size based on the user's configuration selection during the plotter
configuration.

The first time that a user sends a plot to the device after it has
been powered up, and assuming that the AutoCAD paper size selection is
different than the initial paper size setting in the nonvolatile RAM,
the printer will go off-line and display an operator call message.
Pressing the on-line button will dismiss this message and printing
should proceed without error. This error will not appear again until
the user has:

+   Cycled power to the printer
+   Reconfigured the driver for a different paper size


=====================================================================-
WINDOWS-SPECIFIC DRIVER INFORMATION
===================================-

  - AutoCAD WHIP Display List Driver
  - Video Display Drivers (Windows)
  - Digitizer Drivers (Windows)
  - Plotter Drivers (Windows)


AutoCAD WHIP Display List Driver
=================================-
If you are upgrading from an earlier version of AutoCAD R13, you
should read the R13C4NEW Help file (for Windows) or the R13C4NEW.TXT
file (for DOS) which contains Installation Guide Additions. The
sections covering Chapter 1 and Appendix A provide additional
information on the WHIP driver. The information covered in that
document is not repeated here.

After installing/configuring the AutoCAD WHIP display list driver,
refer to the Online Help file accessed from the driver configuration
dialog for additional details concerning the functionality of the
driver.

The WHIP driver is designed to work with the c2, c3 and c4 releases of
AutoCAD. In addition, this driver should also work with the c0 and c1
releases, however it has not been tested with them.

If you have an application that does not appear to be working
correctly with the WHIP driver, it is recommended that you reconfigure
AutoCAD to use the Accelerated driver from Rasterex, or use an
independently developed accelerated driver.

The version of WHIP delivered with AutoCAD R13 c4 does not support
loadable Heidi drivers.


Render and WHIP
---------------
SAVEIMG of full screen does not save the side menu (if it is present),
the menu area is simply filled in with background color. If you need
to save the screen menu, use a different display driver.

The UCS icon may be garbled in render/merged images.


WinG/WHIP Driver-Specific Problems
----------------------------------
WinG depends on Windows display drivers written by independent
hardware manufacturers for much of its speed. Bugs or performance
problems in independently developed display drivers may cause problems
with WinG. In many cases, the video card manufacturer has already
fixed the bug, and upgrading your display driver will often clear away
problems.

The following is a list of known bugs related to specific display
drivers by manufacturer. This list is not intended to slight the
manufacturer or any particular card or driver. A list of stress-tested
configurations is available on the CompuServe WINMM forum and also on
ftp.microsoft.com.

+   Early drivers for Diamond Viper cards included a "Power-Palette"
    option that is no longer supported by Diamond. Diamond recommends
    that you upgrade your drivers if you have this option. WinG may
    be slower when the power palette is enabled.

+   IBM no longer supports the IBM ThinkPad 720c. There are some
    problems using WinG with the ThinkPad 720c display drivers.

+   Cirrus drivers (for some chipsets) prior to version 1.43 have
    many known bugs that have been fixed in more recent drivers. Be
    sure to upgrade your drivers to at least version 1.43 or later,
    except in the case of Cirrius 5434 chipsets, where the latest
    versions are 1.22 and 1.24.

+   Some ATI drivers offer a "Crystal Fonts" option. Turning Crystal
    Fonts on in an 8-bit mode sets up a non-palletized driver that
    can significantly slow the performance of WinG.

+   The ATI Mach 8 Radical drivers cause a number of problems in both
    WinG and in Windows when used with some versions of the ATI
    chipset.

+   The ATI VGA Wonder drivers (W31-*.drv) will crash during a call
    to StretchDIBits in the profiler. Users can run the SVGA256.DRV
    driver that shipped with Windows. Many micro Crystal drivers have
    problems with StretchDIBits, and may crash during profiling.

+   Early ATI Mach 32 PCI cards have a hardware timing problem and
    will hang while blting. ATI will replace these cards at no cost.

+   WinG is incompatible with the #9GXE "TurboCopy" mode. Use the #9
    control panel to disable TurboCopy. This mode is off by default.

+   WinG uses a GetPixel to synchronize with display hardware when
    writing directly to the screen. The ATI Mach 32 driver's GetPixel
    does not work properly, so it is possible to use GDI to draw to
    the screen. Then use WinG to blt to the screen and have them
    overwrite each other. Be careful mixing GDI drawing commands and
    WinG blts to the display.

+   The Orchid MMTLLO.DRV driver for the Prodesigner IIs has
    duplicate system colors which prevents applications from getting
    an identity palette, and greatly reduces the WinG blt speed. A
    workaround is to set SYSPAL_NOSTATIC mode or use the standard
    Tseng ET4000 drivers instead of the mmtllo drivers.

+   When Windows is configured for greater than 256 colors, it has
    been reported that some S3-based video cards have encountered
    anomalies using the WHIP driver in conjunction with AutoCAD
    Render. It is recommended that you configure your Windows video
    display driver for 256 colors if you should encounter any odd
    behavior.

+   We have a report of WHIP incompatibility with the Paradise Bali
    32 Windows display driver. Configuring without that driver (or
    inversely without WHIP) works fine.

+   AutoCAD is unable to load WinG while Microsoft Write is running.


Interactive Pan & Zoom
----------------------
The C3 patch to AutoCAD R13 provides two commands, RTPAN and RTZOOM,
to perform interactive panning and zooming. These pan and zoom
features are only intended for use with the WHIP display driver or a
high performance independently developed display driver. A slow
display driver will impact the performance of these features.

When the RTPAN and RTZOOM commands are active, no other AutoCAD
commands can be executed.

Note: RTPAN and RTZOOM are provided specifically for Release c3.
    Future compatibility with these commands is not guaranteed. For
    example in AutoCAD Release 14, this functionality may be merged
    into improved versions of previously existing commands.

MENU CONFIGURATION

To interact with RTPAN and RTZOOM, you must load the .MNU file to add
these features to the toolbar. Use the following procedure to add the
RTPAN/RTZOOM toolbar menu.

1.  From the Tools menu, choose Customize Menus.
2.  From the Menu Customization dialog box, enter RTPANZM.MNU in the
    File Name edit box.
3.  Choose LOAD.
4.  Choose CLOSE.

You can also enter MENULOAD from the command line to access the Menu
Customization dialog box.

The following sections describe the functionality of interactive
panning and zooming.


PANNING

To pan, enter RTPAN or select the hand icon from the RTPAN/RTZOOM
toolbar. The cursor changes to a hand cursor. By holding the pick
button down, the cursor is locked to its current location relative to
the drawing viewport display coordinate system. Graphics within the
window are moved in the same direction along with the cursor.

When you have reached a logical extent (edge of the drawing space), a
bar appears on the cursor indicating the side where the extent has
been reached. Depending upon whether the logical extent reached is at
the top, bottom, or side of the drawing, the bar that appears is
either horizontal (top or bottom), or vertical (left or right side).

When you release the pick button, panning is discontinued. You can
release the pick button, move the cursor to another location in the
drawing, then press the pick button again and continue to pan the
display from that location.

To exit panning at the new position, press RETURN or ESC.

ZOOMING

To zoom, enter RTZOOM or select the magnifying glass icon from the
RTPAN/RTZOOM toolbar. The cursor changes to a magnifying glass with a
+ and - symbol.

The current drawing window is used to determine the zooming factor.
The RTZOOM command uses half of the window height to move to a zoom
factor of 100%. Holding the pick button down at the mid-point of the
window and moving vertically to the top of the window, zooms in to
100%. Conversely, holding the pick button down at the mid-point of the
window and moving vertically to the bottom of the window, zooms out by
100%.

Note: If the cursor is placed at the bottom of the window, and the
    pick button is pressed down and moved vertically to the top of
    the window, the zoom in factor would be 200%.

When you have reached the zoom in limit, the cursor changes to a -
symbol, indicating that you can no longer zoom in. When you have
reached the zoom out limit, the cursor changes to a + symbol,
indicating that you no longer zoom out.

When you release the pick button, zooming is discontinued. You can
release the pick button, move the cursor to another location in the
drawing, then press the pick button again and continue to zoom the
display from that location.

To exit zooming at the new position, press RETURN or ESC.


Video Display Drivers (Windows)
===============================-


GDI Bypass limitations
----------------------
When the Accelerated Display Driver is configured for GDI bypass ON,
the driver communicates directly with the Windows video driver rather
than with the Windows GDI. This allows faster redraws of AutoCAD
drawings. This method works on Windows 3.1 only. It cannot be enabled
on NT or Windows 95.

If you are having a problem which seems to be related to the video
driver, you can try turning GDI bypass OFF or switching to the non-
accelerated display driver. You might also try upgrading to the video
card's latest driver. Contact the vendor or dealer.


Display drivers which do not support aerial view
------------------------------------------------
If you select the AutoCAD Windows driver (as opposed to the
Accelerated driver) during configuration, you will see a message box
warning that the aerial view is being disabled because the display
driver interface is invalid. You may also see this when using a third
party display driver.

This means that the driver does not support the functions needed by
the aerial view. It is up to the third party driver supplier to add
these functions, as described in the WIN32s ADI driver kit for R13.

It's also possible for third party drivers to provide their own aerial
view and/or magnifying glass which is different from AutoCAD's built-
in one.


Display driver configuration information
----------------------------------------
Different display drivers may store their configuration information in
different places. The Windows display driver (DSACAD.DLL) has no
configuration and thus no configuration information. The accelerated
Windows display driver (DSAI.DLL) places its configuration information
in the acad.ini file, in the section [DSAI]. Other third-party drivers
may store their information in a different section of ACAD.INI or in a
different .INI file altogether. See the documentation for the
particular driver you are using.


Drawing colors in AutoCAD R13 for Windows
-----------------------------------------
AutoCAD R13 for Windows does allow you to redefine the AutoCAD drawing
colors (1=255). You can change the background color (via Preferences)
but not the drawing colors.


Digitizer Drivers (Windows)
===========================-


Microsoft Mouse Driver v9.01
----------------------------
Using the Microsoft Mouse driver 9.01 can cause known errors, such as
GROWSTUB errors. Your pointer might not snap to the default button in
a dialog box; attempts to access the Mouse Manager in the Windows
Control Panel can cause the Mouse Manager to crash and the Control
Panel to quit. You may choose to upgrade your driver; however, this
message does not affect the performance of AutoCAD.


Digitizer Behavior with SKETCH Command
--------------------------------------
(Win 3.1) There is potential for confusion over how the digitizer
should act in AutoCAD Windows. For example, documentation for the
SKETCH command says that the first button (2nd physical button) issues
the 'line to point' command; however, with that button the user gets
the 'record lines and exit' command normally issued by <CR>. AutoCAD
is not broken; the digitizer is acting like a mouse, and the first two
buttons are not digitizer buttons but the left and right mouse
buttons.

Unless TABLET mode is ON in AutoCAD, the digitizer will be a mouse
with one exception for the SKETCH, or any other, command. The
exception is the button that brings up the cursor menu.


Use Latest Wintab Drivers
-------------------------
(Win 3.1) Make sure you have the very latest Wintab driver from your
digitizer manufacturer before configuring AutoCAD for the Wintab ADI
driver. Old versions of Wintab may not work correctly, and some may
even cause AutoCAD to crash. The problem is in the system drivers
provided by the tablet manufacturers, not AutoCAD. Make sure you test
AutoCAD with your version of Wintab before editing your drawing in
AutoCAD.


Reconfiguring a Wintab Driver
-----------------------------
If you have AutoCAD configured for a Wintab digitizer and then
reconfigure the operating system to work with another Wintab
digitizer, you must also reconfigure AutoCAD and select Wintab from
the list of digitizers. The reason for this is that the coordinates
stored in AutoCAD's configuration file marking the location of
digitizer screen areas will change for different Wintab
configurations.


Mixing WINTAB.DLL Files
-----------------------
Different manufacturers of Wintab digitizers supply different versions
of 'WINTAB.DLL', the driver that AutoCAD communicates with from its
ADI driver. Make sure that 'WINTAB.DLL', usually located in your
'window' or 'windows/system' directory, matches the one supplied with
the digitizer. Usually you cannot mix 'WINTAB.DLL' with the drivers
from another manufacturer.


Tablet Screen Area Selection Problem
------------------------------------
In some Wintab implementations, you may need to select the tablet
screen area points twice to get AutoCAD to recognize them. This
problem is in the Wintab drivers supplied by the tablet manufacturer.


Plotter Drivers (Windows)
=========================-


Windows System Printer
----------------------
When running under Windows 3.1, the Windows version of AutoCAD Release
13 uses the Win32s Windows extender to run in 32-bit mode. Some
printer drivers are known to cause erratic behavior when running under
Win32s. We have had the most success with drivers based on version
3.1.4 of the Universal Printer Driver.

If you experience problems printing to the system printer with R13,
you may try contacting your hardware to see if an updated driver is
available. The "About" button in the print setup of most vendor
printer drivers displays the version number of the driver.


=====================================================================-
DOS-SPECIFIC DRIVERS
====================-

  - Video Display Drivers (DOS)
  - Accelerated Display Driver (ADD)
  - Video Chipset/Board Information
  - Digitizer Drivers (DOS)


Video Display Drivers (DOS)
===========================-


Drawing colors in AutoCAD R13 for DOS
-------------------------------------
Many DOS AutoCAD display drivers allow you to redefine the AutoCAD
drawing colors (1=255). They may allow you to choose from among
various mapping schemes or to individually map specific drawing color
numbers to specific RGB values.


Accelerated Display Driver (ADD)
================================-


Configuring for your board
--------------------------
The driver displays a list of boards and chipsets supported by
Autodesk for R13. If your board appears in this list, choose it along
with a resolution that is appropriate for your hardware and monitor
configuration.

If your display board is not listed, then it may still be supported by
the driver through selection of a chipset that the driver supports.
The chipset of your display board is the main graphics circuitry used
on your display board. Consult your display board documentation or
contact the manufacturer for information about which chipset your
board utilizes.

You should also refer to the section titled "Video Chipset/Board
Information" which contains cross-references of many boards and chip
sets.


Unsupported boards
------------------
The driver does not currently support the following boards:

      STB POWERGRAPH XL-24


Changing the background color
-----------------------------
The default background color is black. To change this permanently to
another color, follow these steps:

1.  Reconfigure the driver's custom configuration options. You can do
    this by typing CONFIG at the AutoCAD prompt, then choosing the
    Video display option, or directly by typing DLXCONFIG.
2.  Choose "Menu Color Scheme" from the custom configuration menu.
3.  Next choose the "Background/cursor" setting.
4.  Change the "Graphics background" setting from "0" to another
    valid AutoCAD color index.
5.  If you choose a white background (color index 7), then you must
    also change the "Cursor color" setting from "7" to "0" so that
    the crosshairs will appear.


Text window interactions
------------------------
By default, the driver displays the text screen as a window on the
graphics screen. This window can be moved, resized, or dismissed by
utilizing the window frame and buttons.

To disable the text window permanently and force the text screen to
appear full screen on your monitor, follow these steps:

1.  Reconfigure the driver's custom configuration options. You can do
    this by typing config at the AutoCAD prompt, then choosing the
    Video display option, or directly by typing DLXCONFIG.
2.  Select "Bootup features".
3.  Change the setting of the "Text Window" variable to off.

You may also disable the text window temporarily by using DLXTEXT=N to
disable the text window and using DLXTEXT=Y to re-enable the window.


Dual monitor support
--------------------
During the basic configuration of the product, you are queried for
single or dual screen mode. 'Single' screen mode uses the configured
display device for both text and graphics. 'Dual' screen mode uses a
monochrome card, if present, for display of the text screen. In 'Dual'
mode, there is no pop-up text window and the AutoCAD command area is
reduced to a prompt area, with all other output directed to the
monochrome screen.

There are some devices, however, which are incompatible with
monochrome cards. This either prevents the use of 'Dual' mode in these
cases or corrupts the display. Incompatible devices include:

+   All S3s except S3 801 with S3-core BIOS earlier than 1.1 and S3
    911/924.
+   Cirrus Logic 543X


On-line driver Help
-------------------
In some locales, the driver also implements an on-line Help facility.
To access it, type DLXHELP at the command prompt.


Video Chipset/Board Information
===============================-
The Accelerated Display Driver AutoCAD Release 13 for DOS (RCPDLX.EXP)
is graphics processor general, rather than board specific. This
display list driver represents a "superset" of graphics processors and
video cards supported in R12 DOS. It adds support for SVGA and GUI-X
based cards and chip sets which, based upon our research, became
popular with our customers during the Release 12 product cycle. It is
important to recognize that this driver will not deliver support for
all video cards which have been introduced to the market in the past
six (+/-) months due to low connectivity with Autodesk customers. As
always, board vendors continue to supply high quality and high
performance ADI 4.2 drivers with their products.

In order to facilitate matching of graphics cards to video processors,
this document cross references a wide variety of video cards to the
graphics processors they utilize. Although this document may not
contain references to every graphics card board made, it does list
many popular CAD accelerators and display controllers.

Please use this document as a guide when configuring the Accelerated
Display Driver. The document is divided into two separate sections:

The first section "Graphics Chip Sets & Video Boards" references
graphics processor/accelerator chips, S3 928, Weitek P9000, etc., to
video cards which implement them.

The second portion "Video Boards and their Chips" cross-references
graphics board products (by manufacturer) to the video processor they
utilize.

Graphics cards (and chip sets) which MAY be compatible with supported
processors are listed for informational purposes only and are
identified by an asterisk (*). The list also cross-references
UNSUPPORTED chips and video cards. These cards and chips are marked
with an exclamation point (!) Should you have any question as to the
compatibility of your video card with AutoCAD Release 13 for DOS's
Accelerated Display Driver, please consult the product manufacturer.



Graphics Chip Sets & Video Boards
---------------------------------
(v.53 - 11/3/94)

Chip Vendor
Chip Model              Major OEMs/Board Level Product

Appian/Zymos
Poach 51 (*)      Everex/Viewpoint HC VGA (EV-687)
                  (*)
                  Everex/Viewpoint VGA (EV-623a) (*)
                  Everex/Viewpoint VRAM (EV-623b)
                  (*)
                  Everex/Vision HC (EV-625) (*)
                  Everex/Vision VGA (EV-620) (*)
                  Everex/Vision VGA (EV-626) (*)
AGC-98032 (!)     Appian/Renegade 1280VL-Pro (!)

Ahead Systems
V-5000B (*)       Ahead Systems/VGA WIZARD (*)
                  Ahead Systems/VGA WIZARD/3270 (*)
                  Ahead Systems/VGA WIZARD/DELUXE
                  5(*)

ARTIST Graphics
GPX (!)           ARTIST Graphics/Xj1000 (!)
                  ARTIST Graphics/WinSprint 1000i
                  (!)

ATI Technologies
18800             ATI/VGA EGDE
                  ATI/VGA Wonder
28800             ATI/VGA Wonder XL
                  ATI/VGA Wonder XL24
                  Northgate SlimLine SP 433
38800             ATI/8514 Ultra
                  ATI/8514 Vantage
                  ATI/Graphics Ultra
68800             ATI/Graphics Ultra Plus
                  ATI/Graphics Ultra Pro
                  ATI/Graphics Ultra Pro/EISA
                  ATI/Graphics Ultra Pro/VLB
88800 (!)         ATI/Graphics Ultra Plus Turbo (!)
                  ATI/Graphics Ultra Pro Turbo (!)
                  ATI/Graphics Ultra Pro Turbo PCI
                  (!)
                  ATI/Graphics Xpression (!)

Avance Logic
GUIEngine (!)     Hyubwoo Info Tech/Nudy 1280 (!)

Chips and Technologies (CnT)
82C435/6 (*)      Ahead Systems/EGA WIZARD (*)
                  ATI Technologies/EGA Wonder 800+
                  (*)
                  Boca Research/MultiEGA by Boca (*)
82C451 (*)        PCG/Photon Performa (*)
                  PCG/Photon Performa Turbo (*)
                  STB Systems/STB VGA 800/16 (*)
82C452            Cardinal Technologies/Cardinal 600
                  Metheus/Premier
                  PCG/Photon XV20
82C480 (*)        EIZO/AA-40 (*), AA-41 (*)
                  EIZO/AA-51 (*)
                  EIZO/AC-41 (*)
                  EIZO/AC-51 (*)
                  Image Processing/OverView 1024 (*)
                  Image Processing/OverView 1280 (*)
                  Nth Graphics/Nth 150 (*)
                  PCG/Photon Viper (*)
                  Pixelworks/WhirlWIN (*)
82C481            ELSA America/Winner 1024, 1280
                  ELSA America/Winner/2-1024, 1280
                  Nth Graphics/Nth Edge 1280
                  Pixelworks/WhirlWIN Plus
                  Vibrant Graphics/Vanguard
64300 (*)         Boca Research/Voyager (*)

Cirrus Logic
GD410/420 (*)     Video 7/VEGA VGA (*)
GD510/520 (*)     STB Systems/STB AutoVGA (*)
GD5402 (*)        Boca Research/Boca VGA Plus (*)
                  Boca Research/SVGA 25 (*)
                  Boca Research/SXVGA5 (*)
                  Boca Research/SXVGA1 (*)
GD5404 (*)        Boca Research/Basic VGA (256K) (*)
GD5406 (*)        Boca Research/Basic VGA (512K) (*)
GD5420            Compaq Computer/Presario 400
                  Compaq Computer/ProLiant
                  Compaq Computer/ProLinea Net1
                  Compaq Computer/ProSignia
GD5422            Boca Research/SVGAX2
                  Cardinal Technologies/VGA800
GD5426            Boca/SVGAXL1/2 VLBus SuperX
                  Cardinal Technologies/VGA800XL
                  Compaq Computer/Presario 500
                  Genoa/WindowsVGA 24
                  Genoa/WindowsVGA 24VL
                  STB Systems/Horizon
GD5428            Acer Graphics/L20
                  Acer Graphics/L20E
                  Acer Graphics/L28
                  Boca Research/SuperX VGA v3
                  (SVGAX3)
                  Compaq Computer/Presario 800
                  Compaq Computer/ProLinea MT
                  Focus Info Systems/Cheetah XL28
GD5430 (*)        Orchid Technology/Kelvin 64 (*)
                  Boca/SVGAp1 SuperX VGA PCI (*)
GD5434 (*)        Actix Systems/ProStar 64-PCI (*)
                  Cardinal Technologies/SNAP-VL (*)
                  Diamond Computer/SpeedStar 64 (*)
                  Focus Info Systems/Cheetah 34 (*)
                  Genoa/Genoa 64bit (*)
                  Genoa/WindowsVGA 64 (*)
                  Number Nine/FlashPoint 64 (*)
                  Orchid Technology/Kelvin 64 (*)
                  Compaq Computer/Presario 700 (*)
                  Compaq Computer/Presario 900 (*)
                  RasterOps/ColorImpact 100-DRAM (*)
                  STB Systems/Nitro PCI (*)
                  Truevision/Color Impact 100 (*)
                  Truevision/Video Impact 100 (*)

Compaq Computer Corporation
AVGA              Compaq Advanced VGA
                  Compaq Computer/Concerto
                  Compaq Computer/Contura
                  Compaq Computer/Deskpro/i
                  Compaq Computer/Deskpro/XE
                  Compaq Computer/LTE Lite
                  Compaq Computer/Portable 486
                  Compaq Computer/Systempro
                  Compaq Computer/Systempro LT
                  Compaq Computer/Systempro XL
QVision           Compaq Computer/Deskpro/M
1024I/1280
                  Compaq Computer/QVision
                  1024I/1280I
QVision           Compaq Computer/QVision
1024E/1280        1024E/1280E
QVision 1280/P    Compaq Computer/Deskpro/XL
                  Compaq Computer/QVision 1280/P
QVision 2000 (!)  Compaq Computer/Deskpro/XL (!)

Genoa Corp
GVGA              Genoa Corp/SuperVGA 5400
                  Genoa Corp/SuperVGA 6100
                  Genoa Corp/SuperVGA 6400

Headland
HT216 (!)         Video 7/WIN.VGA (!)
HT209             Video 7/V-RAM II
HT208             Video 7/1024i
HT205             Video 7/V-RAM
                  Video 7/FastWrite

Hitachi
HD63484 (!)       ADEX Corporation/1280/AT (!)
                  ADEX Corporation/Chromograph (!)
                  ARTIST Graphics/ ARTIST 10 (!)
                  ARTIST Graphics/XJ8 (!)
                  ARTIST Graphics/XJ10 (!)
                  ARTIST Graphics/XJ12 (!)
                  ELSA America/Alpha Series (!)
                  ELSA America/Spectra 134 (!)
                  Matrox/PG-640 (!)
                  Matrox/SM-640 (!)

IBM Corp
8514              IBM/8514a
                  Image Adapter/A (*)
VGA               IBM/VGA
XGA               IBM/XGA
                  IBM/XGA-II

IIT
AGX-014 (!)       Hercules/Graphite (!)
                  NDI (Volante)/WARP20 (!)
                  Orchid Technology/Celsius (!)
                  VidTech Micro/GraphMax (!)
AGX-015 (!)       Hercules/Graphite VL (!)
                  NDI (Volante)/WARP24LB, 24LB-2 (!)
                  Orchid Technology/Celsius (!)
                  VidTech Micro/GraphMax LB (!)

Intel
i860 (!)          Alacron/AL860 (!)
                  AQuesT/AQ-1 (!)
                  Division, Ltd. (!)
                  Hauppauge/ADI|860 (!)
                  Hercules SuperStation 3D GB860 (!)
                  Megatek/X-Cellerator 3DX (!)
                  Spea Fire (!)

Matrox
MGA (!)           Matrox/MGA Impression AT (!)
                  Matrox/MGA Ultima Pro (!)
                  Matrox/MGA Ultima PCI (!)
                  Matrox/MGA Ultima 1600 (!)
MGA II (!)        Matrox/Impression Plus (!)
                  Matrox/MGA PCI 2+ (!)
                  Matrox/MGA Ultima Plus (PCI/VL)
                  (!)
                  Matrox/MGA VLB 2+ (!)

Metheus Corp
Omega (!)         Metheus/UGA 1104 (!)
                  Metheus/UGA 1104 Plus (!)
                  Metheus/UGA 1124, 1128 (!)
                  Metheus/UGA 1224, 1228 (!)

NEC
7220AD (!)        ARTIST Graphics/ARTIST 1 (!)
                  ARTIST Graphics/ARTIST 1 Plus (!)
                  Verticom/M16 (!)
                  Verticom/M256 (!)

NCR
77C22E (*)        Boca Research/SuperXVGA (*)
77C32BLT (*)      Alaris/SkyEagle (*)
                  Genoa Systems/Hornet (*)

Oak Technology
OTI037C           Focus Info Systems/2themax VGA 800
                  Beaver Computer/Beaver VGA
OTI067            Focus Info Systems/2themax 6700
OTI077            Paradise/Paradise Value Card

Pixelworks
Clipper (!)       CalComp/DrawingBoard (!)
                  Pixelworks/Clipper Graphics (!)
                  Pixelworks/Ultra Clipper (!)

S3, Inc.
86C801            Actix/GraphicsEngine 32
                  Actix/GraphicsEngine 32 Plus
                  Diamond Computer Systems/Stealth
                  24
                  Focus Info/2theMax True Speed
                  Genoa/WindowsVGA 24+
                  MC2/Rapid View Plus
                  Metheus/Premier 801
                  Mirage/Storm 1280/256
                  NDI (Volante)/WARP10, WARP10PLUS
                  Nth Graphics/S3 Advantage
                  Orchid/Fahrenheit 1280 Plus
                  Orchid Technology/Fahrenheit VA
                  PCG/Torpedo 801
                  Software Integrators/Mercury X1
                  Umax Technology/CX24
                  Video Seven/WIN.PRO
86C805            Actix/GraphicsEngine 32 VLB
                  Diamond Computer/Stealth 24 VLB
                  Hewlett-Packard/UltraVGA-LB
                  NDI (Volante)/WARP10LB, LB-2
                  Orchid Technologies/Fahrenheit VA-
                  LB
                  PCG/Torpedo 805
                  STB Systems/Powergraph VL-24
                  VMI/DesignMaster S3-805-VLB
86C805i           ELSA/Winner 1000 ISA
                  miro Computer/miroCRYSTAL 16Si VLB
                  Software Integrators/Mercury X1VL
86C864 (!)        Actix Graphics Engine 64PCI (!)
                  ELSA/Winner 1000PRO (!)
                  Genoa/Phantom 64 (!)
                  Hewlett-Packard/XM2 PC (!)
                  miro Computer/miroCRYSTAL 20SD (!)
                  Number Nine/#9GXE64 (!)
                  STB Systems/Powergraph Pro PCI (!)
                  VidTech MicroSystems/FastMax P20
                  (!)
86C911            Actix Systems/GraphicsEngine MCA
                  Actix Systems/GraphicsEngine VGA
                  ARTIST Graphics/WinSprint 100 Plus
                  Helio Computers/TurboColor 1280
                  Hewlett-Packard/UltraVGA
                  Matrox/HiPER VGA
                  Metheus/Premier S3
                  NDI (Volante)/AT600
                  Orchid/Fahrenheit 1280(rev 1&2)
                  Pixelworks /WhirlWIN Lite
86C924            Actix/GraphicsEngine 1280
                  Actix/GraphicsEngine 1280 TC
                  Diamond Computer/Stealth VRAM
                  Matrox/HiPer +
                  Matrox/Impression 1024
                  NDI (Volante)/AT600PLUS
                  Orchid/Fahrenheit 1280(rev3)
                  PCG/70-70Deluxe
                  Sixgraph Computing/Wizard 924
86C928            Actix Systems/GraphicsEngine Ultra
                  ARTIST Graphics/WinSprint 900
                  Diamond Computer Systems/Stealth
                  Pro
                  EIZO/OmniVerse 50, 50VL
                  EIZO/OmniVerse 60
                  ELSA America/Winner 1000
                  Focus Information
                  Systems/Roadrunner
                  Metheus/Premier 928
                  Metheus/Premier 928-VL2, VL4
                  miro Computer/miroCRYSTAL 32S VLB
                  Nanao/HA 50, HA 50VL
                  Nanao/HA 60
                  Number Nine/#9GXE (Levels 1,2,3)
                  Number Nine Computer/#9GXE 4MB
                  Number Nine Computer/#9GXE 1600
                  STB Systems/Pegasus VL
86C964 (!)        ELSA/Winner 2000 PRO-PCI (!)
                  miro Computer/miroCRYSTAL 20SV (!)

SuperChips
GD168 (*)         Ahead Systems/Accel-64 (*)

Texas Instruments
34010 (!)         Appian/Rendition I (!)
                  Appian/Rendition I Plus (!)
                  Appian/Rendition II 16/V (!)
                  Appian/Rendition II 256/V (!)
                  Appian/Rendition II 256/V (!)
                  Appian/Rendition IIxe (!)
                  Appian/Rendition III (!)
                  Artist Graphics/ARTIST TI10 (!)
                  Artist Graphics/ARTIST TI12 (!)
                  Compaq Computer/AGC 1024 (!)
                  Desktop Computing/AGA 1024 TC (!)
                  Desktop Computing/AGA 1664 (!)
                  Desktop Computing/AGA Model 1024
                  (!)
                  ELSA America/Gemini/2 Series (!)
                  ELSA America/Gemini10 Series (!)
                  ELSA America/Gemini20 Series (!)
                  Enertronics Research/1024N (!)
                  Hercules/Graphics Station Card (!)
                  Hewlett-Packard/IGC 10 (!)
                  NEC/MVA 1024 (!)
                  NEC/Multisync Graphics Engine (!)
                  Rasterex/Lazer (!)
                  Rasterex/Liberty (!)
                  VMI/Cobra (!)
34020 (!)         Actix/Tiger-10 (!)
                  ARTIST Graphics/XJS (!)
                  ARTIST Graphics/XJS EISA (!)
                  ARTIST Graphics/XJS Lite (!)
                  ARTIST Graphics/XJS MC (!)
                  ARTIST Graphics/WinSprint 200 (!)
                  ARTIST Graphics/WinSprint 200/24
                  (!)
                  ARTIST Graphics/WinSprint 300 (!)
                  ARTIST Graphics/WinSprint 400 (!)
                  ARTIST Graphics/WinSprint 500 (!)
                  Beaver Computer/BCC-20 (!)
                  ELSA America/Gemini20 (!)
                  ELSA America/Gemini200 (!)
                  Hercules/SuperStation XP600 (!)
                  Hercules/SuperStation XP700 (!)
                  Hercules/SuperStation XP800 (!)
                  Hewlett-Packard/IGC 20 (!)
                  Megatek/X-Cellerator 6U,9U,MX (!)
                  National Design/Volante AT800 (!)
                  National Design/Volante AT1000 (!)
                  National Design/Volante AT1600 (!)
                  National Design/Volante AT2000 (!)
                  National Design/Volante MC1000 (!)
                  Number Nine/#9GXi
                  Rasterex/Tracer 1280 (!)
                  Sixgraph Computing/MagicGraf (!)
                  VMI/Cobra Plus (!)
34082 (!)         Artist Graphics/Xj1000 (!)
                  Omnicomp/Texan (!)

Trident
8800 (*)          Trident/TVGA 8816 (*)
8900              Focus Information/2themax VGA 8900
                  Photon Ultima Turbo
                  Trident/TVGA 8916
9000 (*)          Trident/ImpactII (*)
                  Trident/ImpactIII (*)
9400 (*)          Acer Graphics/L90
                  Tecmar/9400 (*)

Tseng Labs
ET3000            EIZO/MD-B10
                  Everex/Viewpoint Premium (EV-643)
                  Focus Information/2themax VGA 1024
                  Orchid Technology/Pro Designer
                  Plus
                  Tecmar/AD
                  Wyse Technologies/Wyse VGA
ET4000AX          Actix Systems/Spectrum HiColor VGA
                  AXL Technologies/AXL 4000RG
                  AXL Technologies/AXL 4000GA VGA
                  Boca Research/SuperVGA
                  Boca Research/SuperXVGA
                  Cardinal Technologies/700 Series
                  Cardinal Technologies/SNAP
                  Cardinal Technologies/SNAPplus
                  Compaq/Presario 600
                  Compaq/ProLinea 486
                  Definicon/CAD RACE
                  Definicon/HiRes 1024
                  Diamond Computer/SpeedStar
                  Diamond Computer/SpeedStar 24
                  Diamond Computer/SpeedStar Plus
                  EIZO/VA 41
                  EIZO/VA 42
                  Focus Information/2themax 4000
                  Genoa/Multimedia VGA 7900
                  Metheus/Premier 1meg
                  Metheus/Premier HiColor
                  Nth Graphics/Nth Engine/124
                  Orchid Technologies/Pro DesignerII
                  Orchid Technologies/Pro 800
                  Prism/ Excelsior
                  Prism/VGA Eclipse
                  Sigma Designs/VGA Legend
                  Sigma Designs/VGA Legend II
                  SOTA Technology/1280i
                  STB Systems/STB EM+ Powergraph
                  STB Systems/ERGO
                  STB Systems/MVP
                  Truevision/Video VGA 8
                  Truevision/Video VGA 16
                  VMI/DesignMaster VGA
ET4000/32         Compaq/ProLinea
                  Hercules/Dynamite VL
ET4000/W32i (*)   Genoa Systems/Phantom32i 8900VL
                  (*)
                  Hercules/Dynamite (*)
                  Hercules/Dynamite Pro VL (*)
ET4000/W32p       Cal Graphics/SunTracer2000 (*)
                  miro Computer/miroCRYSTAL 20TD (*)
                  Focus Information/Truespeed (*)

Weitek
8720 (!)          Megatek/ESPRIX (!)
Power9000         Cardinal Technologies/WARPspeed
                  Dell Computer
                  Diamond Computer/Viper PCI
                  Diamond Computer/Viper VLB
                  Focam Technologies/Eureka
                  Genoa/Blitz 24
                  Micron/466VL Magnum
                  Orchid Technologies/Celsius
                  Orchid Technologies/P9000VLB
                  PCG/Photon GXA9000
                  Zeos/486DX2-66
P9100 (!)         Diamond Computer/Viper Pro PCI (!)
                  miro Computer/miroCRYSTAL 20PV (!)
                  miro Computer/miroCRYSTAL 40PV (!)
                  RasterOps/Color Impact Pro 1000
                  (!)
                  Truevision/Color Impact Pro 1000
                  (!)

Western Digital
PVGA-1A (*)       Acer VGA (*)
                  Compaq VGA (*)
                  Maxlogic/MaxVGA/16 (*)
                  Maxlogic/MaxVGA/1024 (*)
                  Paradise/VGA Professional (*)
WD90C00           Paradise/VGA 1024
WD90C11/C11+ (*)  Compaq Computer/ProLinea 386 (*)
                  Compaq Computer/ProSignia8
                  Dell Computer VGA (*)
WD90C24(A2) (*)   Compaq Computer/Contura 400 (*)
                  Compaq Computer/LTE Elite (*)
WD90C30           AST Research VGA (*)
                  Paradise/Paradise Super VGA Card
                  (*)
WD90C31           Diamond Computer/SpeedStar 24x
                  Paradise/Accelerator for Windows
WD95C00           ADEX/8514/AT
                  ADEX/8514MC
                  Matrox/MG-104, 108
WD95C01           Matrox/MG-124, 128



Video Boards and their Chips
----------------------------
(v.53 - 11/3/94)

The purpose of this section is to provide guidance to customers who
wish to configure a graphics card for use with Release 13 for DOS's
Accelerated Display Driver.

As noted earlier in this document, the AutoCAD Release 13 for DOS
Accelerated Display Driver supports graphics processors that were
popular with Release 12 customers. Almost all of the newer graphics
accelerators now available on the market include high performance DOS
ADI 4.2 drivers for AutoCAD Release 13.

Please use this document as a guide only, as not all modes or
configuration options are available to video cards which use
compatible processors. In some instances, functionality may be limited
to certain resolutions and color depths.


Vendor/Product    CHIP Vendor       CHIP

Acer Graphics
CL                Cirrus Logic      GD5428
L20/L20E          Cirrus Logic      GD5428
L28               Cirrus Logic      GD5428
L90 (*)           Trident           9400

The Acer CL, L20, L20E and L28 video cards should be configured for
use with the Accelerated Display Driver by selecting the generic
Cirrus Logic GD542x chip option. Full resolution and color depths of
these cards should be available under this option.

The Acer L90 card should function with the AutoCAD Release 13 DOS
Accelerated Display Driver by selecting the generic Trident 8900 chip
configuration option. Not all acceleration modes, resolutions or color
depths supported by the Trident 9400 processor will be available to
the L90 under this configuration. ADI 4.2 driver support is obtainable
directly from Acer and a number of independent driver developers.

Actix Systems, Inc.
GraphicsEngine 1280      S3, Inc.            86C924
GraphicsEngine 1280 TC   S3, Inc.            86C924
GraphicsEngine 32        S3, Inc.            86C801
GraphicsEngine 32 Plus   S3, Inc.            86C801
GraphicsEngine 32 VLB    S3, Inc.            86C805
GraphicsEngine 64 (*)    S3, Inc.            86C864
GraphicsEngine MCA       S3, Inc.            86C911
GraphicsEngine Ultra     S3, Inc.            86C928
GraphicsEngine VGA       S3, Inc.            86C911
ProStar 64-PCI (*)       Cirrus Logic        GD5434
Spectrum HiColor VGA     Tseng Labs          ET4000AX
Tiger-10 (!)             Texas Instruments   34020

The Actix GraphicsEngine Series of video adapters are all supported by
R13's DOS Accelerated Display Driver generic S3 configuration options
except for the GraphicsEngine 64. The S3 86C864-based GraphicsEngine
64 will function with limited functionality when configured for either
VESA or VGA modes.

The Cirrus Logic GD5434-based Actix ProStar 64-PCI may be operated
with limited functionality by configuring the R13 DOS Accelerated
Display Driver for the generic Cirrus Logic GD542x option.

Configure Actix' Spectrum HiColor VGA for use with the Release 13
Accelerated Display Driver by selecting Tseng Labs ET-4000 from the
graphics chip portion of the menu.

The Texas Instruments 34020 based Tiger-10 is not supported by the
Release 13 supplied display driver. Actix Systems and many independent
developers offer high performance AutoCAD Release 13 DOS (P386) ADI
4.2 drivers for use with TI 340x0 based graphics controllers. Contact
Actix Systems for more details.

ADEX Corporation
Chromograph (!)      Hitachi              HD63484
1280/AT (!)          Hitachi              HD63484
8514/AT              Western Digital      WD95C00/01
8514/MC              Western Digital      WD95C00/01

The ADEX 8514 series of WD95C0x-based cards are supported via the
generic WD95C0x configuration option supplied in R13's Accelerated
Display Driver.

The ADEX Chromograph and 1280/AT utilize the HD63484 graphics
processor which is not supported and no configuration recommendation
is available to support these cards.

Ahead Systems
Accel-64 Windows     SuperChips           GD168
Accelerator (*)
EGA WIZARD (*)       CnT                  82C435/6
VGA WIZARD (*)       Ahead Systems        V-5000
VGA WIZARD/3270 (*)  Ahead Systems        V-5000
VGA WIZARD/DELUXE    Ahead Systems        V-5000
5.0 (*)

The Chips and Technologies 82C435/6 based EGA Wizard may function in
VGA mode (640x480x16 colors) when the Accelerated Display Driver is
configured for IBM VGA. Due to the age of this video card, customers
with this product should consider upgrading their video subsystem to a
higher resolution environment.

Limited resolution and color depth support may be obtained the V-5000B
based for Ahead Systems' VGA WIZARD series by configuring for standard
VGA. Higher resolution or color depth can be obtained through use of a
VESA (Video Electronic Standards Association) driver.

The Ahead Accel-64 Windows Accelerator is based on the unsupported
SuperChips GD168 video accelerator. Configure this card using the VESA
option.

Ahead Systems may not offer VESA support driver for all of their
cards. ADI 4.2 driver support is available for most Ahead Systems
boards directly from the manufacturer and a number of independent
driver developers.

Alacron, Inc.
AL860 (!)         Intel             i860

No support is offered for i860 based cards such as the Alacron AL860.
Contact the manufacturer regarding the possible existence of DOS P386
ADI 4.2 driver support.

Alaris
SkyEagle (*)      NCR               77C32BLT

The 77C32BLT based Alaris SkyEagle should be configured for use with
R13 by selecting the DOS Accelerated Display Driver's VESA option.
Additional high performance ADI driver support may be available.
Contact the manufacturer for information on how to obtain DOS Release
13 drivers.

Appian Technology (Renaissance)
Legacy II (EGA) (!)      Renaissance GRX      6480/81
Rendition I (!)          Texas Instruments    34010
Rendition I Plus (!)     Texas Instruments    34010
Rendition II 16/V (!)    Texas Instruments    34010
Rendition II 256/V (!)   Texas Instruments    34010
Rendition II 256/V (!)   Texas Instruments    34010
Rendition IIxe (!)       Texas Instruments    34010
Rendition III (!)        Texas Instruments    34010
Renegade (EGA) (!)       Renaissance          GRX
Renegade 1280VL-Pro (!)  Appian               AGC-98032

Autodesk does not supply support for the Appian (Renaissance) graphics
controllers in the Release 13 box. Appian Technology delivers their
high performance Virtuoso ADI 4.2 Display List Driver for use with
AutoCAD Release 13. Please contact the manufacturer for more
information.

AQuesT, Inc.
AQ-1 (!)                 Intel                i860

No support is offered for i860 based cards such as the AQuesT AQ-1.
The manufacturer of this product no longer is in business and the
possible existence of DOS P386 ADI 4.2 driver support is unlikely.

ARTIST Graphics
ARTIST 1 (!)             NEC                  7220AD
ARTIST 1 Plus (!)        NEC                  7220AD
ARTIST 1500 (*)          S3, Inc.             86C864
ARTIST TI10 (!)          Texas Instruments    34010
ARTIST TI12 (!)          Texas Instruments    34010
XJ8 (!)                  Hitachi              HD63484
XJ10 (!)                 Hitachi              HD63484
XJ12 (!)                 Hitachi              HD63484
Xj1000 (!)               ARTIST               GPX
XJS (!)                  Texas Instruments    34020
XJS EISA (!)             Texas Instruments    3020
XJS Lite (!)             Texas Instruments    34020
XJS MC (!)               Texas Instruments    34020
WinSprint 100 +          S3, Inc.             86C911
WinSprint 200 (!)        Texas Instruments    34020
WinSprint 200/24 (!)     Texas Instruments    34020
WinSprint 300 (!)        Texas Instruments    34020
WinSprint 400 (!)        Texas Instruments    34020
WinSprint 500 (!)        Texas Instruments    34020
WinSprint 900            S3, Inc.             86C928
WinSprint 1000 (!)       ARTIST               GPX

Only the S3 based WinSprint 900 and WinSprint 100+ are fully supported
by AutoCAD's Release DOS Accelerated Display Driver. The ARTIST 1500
uses S3's 86C864 processor and is partially supported under the VESA
option. ARTIST's GT Express product provides high performance ADI 4.2
DOS Display List support for use with AutoCAD Release 13. Please
contact ARTIST Graphics at 1-800-6ARTIST for information on how to
obtain current driver revisions.

ATI
8514 Ultra               ATI Technologies     38800
8514 Vantage             ATI Technologies     38800
EGA Wonder 800/800+ (*)  Chips and Tech       82C435/6
Graphics Ultra           ATI Technologies     38800/28800
Graphics Ultra Plus      ATI Technologies     68800
Graphics Ultra Plus      ATI Technologies     88800
Turbo (!)
Graphics Ultra Pro       ATI Technologies     68800
Graphics Ultra Pro/EISA  ATI Technologies     68800
Graphics Ultra Pro       ATI Technologies     88800
Turbo (!)
Graphics Ultra Pro       ATI Technologies     88800
Turbo PCI (!)
Graphics Ultra Pro       ATI Technologies     88800
Turbo PCI (!)
Graphics Ultra XLR       ATI Technologies     68800
Graphics Vantage         ATI Technologies     38800
Graphics Wonder          ATI Technologies     28800
Graphics Xpression (!)   ATI Technologies     88800CX
VGA EDGE                 ATI Technologies     18800
VGA Wonder               ATI Technologies     18800
VGA Wonder XL            ATI Technologies     28800

Almost all ATI cards are supported by Release 13 with a few minor
exceptions which are listed as follows:

The CnT 82C435/6 based ATI EGA Wonder 800+ may function by configuring
the Accelerated Display Driver for VGA mode (640x480x16 colors). Due
to the age of this video adapter, customers with this product should
consider upgrading their video subsystem to a higher resolution
environment.

The ATI Graphics Ultra Plus Turbo, Graphics Ultra Pro Turbo, and
Graphics Xpression Series are based upon ATI's 88800 (mach 64)
graphics accelerator. Utilize the VESA configuration option for mach
64 based video cards in AutoCAD Release 13 for DOS.

ATI Technologies provides high performance ADI 4.2 DOS Display List
drivers for use with AutoCAD Release 13. Please contact ATI for
information on how to obtain current driver revisions.

AXL Technologies
AXL 4000RG              Tseng Labs, Inc.     ET4000
AXL 4000GA VGA          Tseng Labs, Inc.     ET4000
AXL 1280GA S3           S3, Inc.             86C924

The AXL graphics cards listed above should deliver full functionality
when used with the supplied Accelerated Display Driver for R13 DOS.
Use the Tseng Labs ET-4000 option for the AXL 4000 series cards. The
AXL 1280GA board should be configured using the S3 924 selection.

Beaver Computer Corporation
BCC TIGA-10 (!)         Texas Instruments    34010
BCC TIGA-20 (!)         Texas Instruments    34020
Beaver VGA              Oak Technology       OTI037C

Configure AutoCAD Release 13 using the Oak Technology OTI-0x7 generic
chip offering if you use BCC's Beaver VGA. Release 13 does not offer
support for Beaver Computers TIGA series of display adapters. A number
of Registered ADI Driver Developers offer Release 13 ADI 4.2 TIGA
drivers.

Boca Research
Basic VGA (256K) (*)    Cirrus Logic         GD5404
Basic VGA (512K) (*)    Cirrus Logic         GD5406
Boca VGA Plus (*)       Cirrus Logic         GD5402
Boca XGA (*)            SGS Thompson         SGS-XGA
MultiEGA by Boca (*)    CnT                  82C435/6
SuperVGA by Boca        Tseng Labs           ET4000AX
(SXVGA1)
SuperX VGA v1           Tseng Labs           ET4000AX
SuperX VGA v2 (*)       NCR                  77C22E
SuperX VGA v3 (SVGAX3)  Cirrus Logic         GD5426
SVGA 25 (*)             Cirrus Logic         GD5402
SXVGA5                  Cirrus Logic         GD5420
SuperVGA by Boca        Cirrus Logic         GD5420
(SXVGA1)
SVGAX2                  Cirrus Logic         GD5422
VL-Bus SuperX           Cirrus Logic         GD5426
Accelerator
SuperX VGA PCI (SVGAP1) Cirrus Logic         GD5430
(*)
Voyager (SVCXL1/2) (!)  Chips and Tech       64300

Boca Research's MultiEGA by Boca uses Chips and Technologies 82C435/6
graphics chip which may function in VGA mode (640x480x16 colors) when
the Accelerated Display Driver is configured for standard VGA. Due to
the age of this graphics card, Autodesk encourages any customer with
this product to upgrade their video subsystem to a higher resolution
environment.

Boca's Basic VGA series SVGA 25 Cirrus Logic GD540x based video
adapters should operate with limited performance and functionality by
configuring the Release 13 DOS Accelerated Display Driver for the
Cirrus GD542x chip, VESA or standard VGA.

The SuperVGA by Boca and Boca's SuperX VGA v1 utilize the generic
Tseng Labs ET4000 configuration option. Use of this configuration
should deliver full performance and functionality. Version 2 of the
SuperX VGA (v2) is based on NCR's 77C22E chip and will operate in VESA
compatible mode. Boca's SuperX VGA v3 (SVGAX3), SuperVGA by Boca
(SXVGA1), SVGAX2, and VL-Bus SuperX Accelerator are fully functional
when using the Release 13 DOS Accelerated Display Driver generic
Cirrus Logic GD542x configuration option.

The Boca XGA may operate by configuring for IBM XGA, VESA or VGA. The
Boca Research Voyager uses CnT's 64300 and support may be limited to
VESA modes.

CalComp - Display Products Division
DrawingCard (!)      Pixelworks       Clipper

No support is offered for this video card by Release 13's DOS
Accelerated Display Driver, but CalComp does supply an ADI 4.2 driver
which supports AutoCAD Release 13. Contact the manufacturer for more
details.

California Graphics & Peripherals
SunTracer 2000 (*)      Tseng Labs           ET4000/W32p

Basic functionality can be obtained for the Suntracer 2000 by
selecting the Tseng ET4000 or VESA configuration options. California
Graphics provides high performance drivers ADI 4.2 DOS drivers for use
with Release 13. Contact the manufacturer for more details.

Cardinal Technologies, Inc.
SNAP                    Tseng Labs           ET4000
SNAPplus                Tseng Labs           ET4000
SNAP-VL (*)             Cirrus Logic         GD5434
Cardinal 600            Chips and Tech       82C452
VGA800                  Cirrus Logic         GD5422
VGA800XL                Cirrus Logic         GD5426
WARPspeed               Weitek               P9000

The SNAP and SNAPplus video adapters should be configured using the
Tseng Labs ET4000 option. Select VESA for the SNAP-VL board. The
Cardinal 600 is supported by picking the Chips and Technologies 82C452
generic option. Cardinal's VGA800 and VGA800XL use the driver's Cirrus
Logic GD542x configuration option. The Weitek P9000 selection will
provide full performance and functionality for the Cardinal WARPspeed
graphics accelerator.

Compaq Computer
AGC 1024 (!)            Texas Instruments    34010
Advanced VGA            Compaq Computer      AVGA
Compaq VGA              Western Digital      PVGA-1A
Compaq VGC (!)          Compaq Computer      VGC
Concerto                Compaq Computer      AVGA
Contura                 Compaq Computer      AVGA
Contura 400 (*)         Western Digital      WD90C24(A2)
Deskpro/i               Compaq Computer      AVGA
Deskpro/M               Compaq Computer      AVGA
Deskpro/XE              Compaq Computer      AVGA
Deskpro/XL              Compaq Computer      QVision
(some use QV2000)                            1280/P
LTE Elite (*)           Western Digital      WD90C24(A2)
LTE Lite                Compaq Computer      AVGA
Portable 486            Compaq Computer      AVGA
Presario 400            Cirrus Logic         GD5420
Presario 500            Cirrus Logic         GD5426
Presario 600            ET4000AX             Tseng Labs
Presario 700 (*)        Cirrus Logic         GD5434
Presario 800            Cirrus Logic         GD5428
Presario 900 (*)        Cirrus Logic         GD5434
ProLiant                Cirrus Logic         GD5420
ProLinea 386            Western Digital      WD90C11
ProLinea 486            ET4000AX             Tseng Labs
ProLinea MT             Cirrus Logic         GD5428
ProLinea Net1           Cirrus Logic         GD5420
ProSignia -             Cirrus Logic         GD5420
Compaq used 2 chips
ProSignia               Western Digital      WD90C11
QVision 1024E/1280E     Compaq Computer      QVision
                                             1024E/1280E
QVision 1024I/1280I     Compaq Computer      QVision
                                             1024I/1280I
QVision 1280/P          Compaq Computer      QVision/1280P
QVision 2000 (!)        Matrox               MGA2
Systempro (/LT, /XL)    Compaq Computer      AVGA

Almost all Compaq display controllers and video adapters are supported
except for the following devices.

The TI 34010 based AGC 1024 is supported by Compaq's ADI 4.2 DOS
Display List Driver. Contact Compaq for more information. The VGC
adapter may function when configured for standard VGA. The Contura 400
and LTE Elite use the WD90C24 processor, select the WD90C31 or VESA
options. The Presario 700 may operate with basic functionality by
configuring with the Cirrus Logic GD542x processor or VESA selections.
Support for the QVision 2000 graphics accelerator is not provided by
R13's supplied driver. Contact Compaq for information on obtaining R13
drivers.

Desktop Computing
AGA 1024 TC (!)         Texas Instruments    34010
AGA 1664 (!)            Texas Instruments    34010
AGA Model 1024 (!)      Texas Instruments    34010

Release 13 does not support the TI 34010 controller. Contact the
manufacturer for information on obtaining a driver.

Definicon
CAD RACE                Tseng Labs, Inc.     ET4000
HiRes 1024              Tseng Labs, Inc.     ET4000

The Definicon ET-4000 based video cards should operate by selecting
the generic Tseng Labs ET4000 configuration option.

Diamond Computer Systems (Diamond MultiMedia Systems)
SpeedStar               Tseng Labs           ET4000AX
SpeedStar 24            Tseng Labs           ET4000AX
SpeedStar 24x           Western Digital      WD90C31
SpeedStar 64 (*)        Cirrus Logic         GD5434
SpeedStar HiColor       Tseng Labs           ET4000AX
SpeedStar Plus          Tseng Labs           ET4000AX
SpeedStar Pro           Tseng Labs           ET4000AX
SpeedStar VGA           Tseng Labs           ET4000AX
Stealth 24              S3, Inc.             86C801
Stealth 24 VLB          S3, Inc.             86C805
Stealth 32              Tseng Labs           ET4000/W32P
Stealth Pro             S3, Inc.             86C928
Stealth VRAM            S3, Inc.             86C924
Viper SE                Weitek               Power 9000
Viper VLB               Weitek               Power 9000
Viper PCI               Weitek               Power 9000
Viper PCI Pro (*)       Weitek               Power 9100

Autodesk's Accelerated Display Driver supports most of Diamond
Computer's video graphics accelerators with a few exceptions. The
SpeedStar 64 should operate configured for VESA mode or under the
generic Cirrus 542x option. The Viper PCI Pro may operate configured
under the generic Weitek P9000 or VESA options.

EIZO
AA-40, AA-41 (*)        Chips & Tech         82C480
AA 51 (*)               Chips & Tech         82C480
AC-41 (*)               Chips & Tech         82C480
AC-51 (*)               Chips & Tech         82C480
MD-B10                  Tseng Labs           ET3000
OmniVerse 50, 50VL      S3, Inc.             86C928
OmniVerse 60            S3, Inc.             86C928
VA 41                   Tseng Labs           ET4000
VA 42                   Tseng Labs           ET4000

The EIZO AA and AC series adapters should be operable with the R13 DOS
Accelerated Display driver when configured for either the IBM 8514/A
or the CnT 82C481. EIZO's MD-B10 should be configured for Tseng Lab's
ET3000 chip. The OmniVerse series is supported under the generic S3
911/924/928 option, while the VA series utilizes the Tseng ET4000
configuration.

EIZO AA-40,41,51, AC-41,51 use the Chips and Technologies 82C480
graphics accelerator chip:

The EIZO cards should be compatible with a number of the Accelerated
Display List Driver's configuration options. The CnT 82C480 is IBM
8514/A compatible and should also operate when the driver is
configured for the CnT82C481. EIZO (or Nanao) provides ADI drivers for
their video cards. Please consult the manufacturer or your dealer for
information on obtaining current versions.

ELSA America
Alpha Series (!)        Hitachi             HD63484
Gemini/2 Series (!)     Texas Instruments   34010
Gemini10 Series (!)     Texas Instruments   34010
Gemini20 Series  (!)    Texas Instruments   34010
Spectra Series (!)      Hitachi             HD63484
Winner 1000             S3, Inc.            86C928
Winner 1000 ISA         S3, Inc.            86C805i
Winner 1000PRO (*)      S3, Inc.            86C864
Winner1024              Chips & Tech        82C480/481
Winner1280              Chips & Tech        82C481
Winner 2000 - 4         S3, Inc.            86C928
Winner 2000 PRO-PCI     S3, Inc.            86C964
(*)
Winner 2000 PRO-VL (*)  S3, Inc.            8C964

The HD63484 based Alpha and Spectra series, along with the TI 340x0
Gemini family of ELSA video adapters, are not supported with the
Release 13 Accelerated Display Driver. ELSA provides high performance
ADI 4.2 drivers for the majority of their graphics controllers.
Contact the manufacturer for details on obtaining driver updates.

Enertronics Research, Inc
1024N (!)               Texas Instruments   34010

The Enertronics 1024N video adapter is not supported with the Release
13 Accelerated Display Driver. Please contact the manufacturer for
information on obtaining a DOS ADI 4.2 driver. As an alternative,
there are a number of Registered ADI Driver Developers who develop
TIGA based ADI 4.2 drivers which may support the 1024N board. Contact
your Autodesk reseller for more details.

Everex
Viewpoint HC VGA        Appian (Zymos)        Poach 51
(EV-687) (*)
Viewpoint Premium       Tseng Labs            ET-3000
(EV-643)
Viewpoint VGA           Appian (Zymos)        Poach 51
(EV-623a) (*)
Viewpoint VRAM          Appian (Zymos)        Poach 51
(EV-623b) (*)
Vision VGA (EV-620) (*) Appian (Zymos)        Poach 51
Vision HC (EV-625) (*)  Appian (Zymos)        Poach 51
Vision VGA w/Overlay    Appian (Zymos)        Poach 51
(*)

Everex cards (Viewpoint Premium) which utilize the Tseng Labs ET3000
chip are supported based by this driver. Select the generic Tseng
ET3000 configuration option if your Everex board has this chip.

The Everex Viewpoint and Vision adapters which use the Poach 51 chip
set should be compatible with Release 13's standard VGA mode. The
Release 13 driver does not offer support for extended color depth or
resolution for the Poach 51 chip. AutoCAD Release 12's ADI 4.2
SuperVGA driver (rcsvadi.exp) DOES support some cards based on this
chip and will function with R13. Contact your Autodesk reseller for
more information on how to obtain this driver.

Evershine
Evershine ET4000        Tseng Labs            ET-4000
Evershine ET4X          Tseng Labs            ET-4000

Tseng Labs ET4000 based video adapters such the Evershine ET series
are supported with the Release 13 for DOS Accelerated Display Driver.
Select the generic Tseng ET4000 configuration option if you have one
of the above listed Evershine video cards.

Focam Technologies, Inc.
Eureka Display Card     Weitek                P9000

The Eureka card may function with the generic Weitek P9000 option.
Alternatively, utilize the VESA configuration for Release 13 DOS
support. Contact Focam Technologies for more information regarding ADI
4.2 driver support of the Eureka card with Release 13.

Focus Information Systems
2themax VGA 800         Oak Technology       OTI-037
2themax VGA 1024        Tseng Labs           ET3000
2themax VGA 4000        Tseng Labs           ET4000AX
2themax VGA 6700        Oak Technology       OTI-067
2themax VGA 8900        Trident              8900
Cheetah XL28            Cirrus Logic         GD5428
Cheetah 34 (*)          Cirrus Logic         GD5434
Roadrunner (*)          S3, Inc.             86C864
Truespeed (*)           Tseng Labs           ET4000W32p

Focus Information's 2themax VGA series of graphics adapters are
supported with the Release 13 for DOS Accelerated Display Driver. The
VGA 800 and VGA 6700 use the generic OAK Technology OTI-0x7 selection.
Pick the Tseng Labs ET3000 option for the VGA 1024 and ET4000 for the
VGA 4000. The VGA 8900 is configured by selecting our Trident chip
option.

The Cheetah XL28 is supported though the driver's Cirrus Logic GD542x
chip set configuration option. The GD5434 based Cheetah 34 may operate
using the same selection, but with less functionality that the
processor supports. For the Roadrunner you can try configuring using
the generic S3 801/805 option, but functionality and resolution is
likely to be limited. If you have a Focus Information Truespeed
graphics accelerator, the Tseng Labs ET4000 should operate, but you
will not experience the native acceleration modes. For those Focus
video accelerators which may operate in a compatible mode, you may
achieve higher performance and resolution by using the VESA
configuration option.

Galagraph
Galaxy 1024 (!)         Galagraph            Custom

No Release 13 for DOS support from Autodesk exists for this adapter.
Contact the manufacturer for more information on how to obtain support
for this controller. Due to the age of this device, Autodesk suggests
that you consider upgrading your video subsystem.

General Business Machines Corp.
Mirage II 4000          Tseng Labs           ET-4000
Mirage IIs Series (31   Tseng Labs           ET-4000
& 48)
Mirage Storm Series     S3, Inc.             86C928

All of the GBM Mirage II and Mirage Storm graphics adapters listed
above are supported by AutoCAD Release 13's DOS Accelerated Display
Driver. Configure using the appropriate graphics processor options as
noted above.

Genoa Corp
Blitz 24                Weitek               P9000
Genoa 64bit (*)         Cirrus Logic         GD5434
Hornet 8300 (*)         NCR                  77C32BLT
Multimedia VGA 7900     Tseng Labs           ET4000
Phantom32i 8900VL (*)   Tseng Labs           ET4000/W32i
Phantom 64 (*)          S3, Inc.             86C864
SuperVGA 5400 Series    Genoa                GVGA
SuperVGA 6100 Series    Genoa                GVGA
SuperVGA 6400 Series    Genoa                GVGA
WindowsVGA 24 (8500)    Cirrus Logic         GD5426
WindowsVGA 24VL         Cirrus Logic         GD5426
WindowsVGA 64 (*)       Cirrus Logic         GD5434

Genoa's SuperVGA series of graphics adapters are supported with the
Release 13 for DOS Accelerated Display Driver as are the WindowsVGA
24, Multimedia VGA 7900 and the Blitz 24. Configure using the
appropriate graphics processor options as noted above.

Hauppauge Computer Works, Inc.
Hauppauge ADI/860 (!)   Intel              i860

No support is offered for i860 based cards such as Happaugue's.
Contact the manufacturer regarding obtaining a DOS P386 ADI 4.2
driver.

Helio Computers, Inc.
TurboColor 1280         S3, Inc.            86C911

As Heilo's TurboColor 1280 uses the S3 911 chip set, it will be
supported with the Release 13 for DOS Accelerated Display Driver.
Please configure by selecting the S3 911/924/928 chip option.

Hercules Computer Technology
CHROME (!)              Texas Instruments  34020
Dynamite (*)            Tseng Labs         ET4000/W32i
Dynamite Pro VL (*)     Tseng Labs         ET4000/W32i
Graphics Card (!)       Hercules           Custom
Graphics Card Plus (!)  Hercules           Custom
Graphics Station Card   Texas Instruments  34010
(!)
Graphite (!)            IIT                AGX-014
Graphite VL (!)         IIT                AGX-015
InColor Card (!)        Hercules           Custom
SuperStation 3D GB820   Texas Instruments  34020
(!)
SuperStation 3D GB860   Intel              i860 & TI 34020
(!)
SuperStation XP600 (!)  Texas Instruments  34020
SuperStation XP700 (!)  Texas Instruments  34020
SuperStation XP800 (!)  Texas Instruments  34020

TI 340x0, IIT AGX and Intel i860 based graphics controllers such as
Hercules' CHROME, Graphics Station, Graphite and SuperStation 3D or XP
series are not supported with the Release 13 DOS Accelerated Display
Driver. Please contact Hercules for information on obtaining an ADI
4.2 driver to support these products. As an alternative, there are a
number of Registered ADI Driver Developers who develop TIGA based ADI
4.2 drivers which may support the CHROME and SuperStation XP.

AutoCAD Release 13 customers who use the Hercules Graphics or InColor
cards may encounter difficulty obtaining a DOS P386 ADI 4.2 driver to
these devices. You are encouraged to upgrade your video subsystem.

Hewlett-Packard
IGC 10 (!)              Texas Instruments    34010
IGC 20 (!)              Texas Instruments    34020
UltraVGA                S3, Inc.             86C911
UltraVGA-LB             S3, Inc.             86C805

The HP IGC 10 and 20 graphics controllers are not supported by Release
13's DOS Accelerated Display Driver. Please contact the manufacturer
for information on obtaining a DOS ADI 4.2 driver. As an alternative,
there are a number of Registered ADI Driver Developers who develop
TIGA based ADI 4.2 drivers which may support the IGC series of
controllers.

The UltraVGA series of graphics accelerators are supported by the
generic S3 configuration option. Configure these boards according to
the chip set used. Refer to the above listing for information as to
which processor the video card has.

Hyubwoo Information Technology (Herald Info Tech)
Nudy 1280 is based upon the Avance Logic GUIengine (!):

No compatible configuration option exists for the Nudy 1280. It may be
possible to use the card in VGA mode for basic configuration purposes.
HIT includes a high performance ADI 4.2 DOS Display List with every
display controller. Please contact the manufacturer for information on
how to obtain current driver versions.

IBM
8514/A                  IBM               8514/A
CGA (!)                 IBM               CGA
EGA (!)                 IBM               EGA
Image Adapter/A (!)     IBM               Custom
VGA                     IBM               VGA
XGA                     IBM               XGA
XGA-II                  IBM               XGA

The IBM CGA and EGA adapters are not supported by AutoCAD Release 13
due to their limited resolution and color depth. Should you be using
either adapter you are encouraged to upgrade your video subsystem.

The Image Adapter/A is not directly supported but may function in VGA
mode with the DOS AutoCAD Release 13 Accelerated Display Driver.
Contact the manufacturer for more details regarding ADI 4.2 driver
support for this graphics adapter.

IBM's 8514/A, VGA, and XGA series of adapters are supported. Select
the appropriate configuration option from the DOS Accelerated Display
Driver menu.

Image Processing Systems
OverView 1024 (*)       Chips & Tech      (CnT)82C480
OverView 1280 (*)       Chips & Tech      (CnT)82C480

The OverView series of cards from Image Processing systems is
compatible with the IBM 8514/A and CnT 82C481 configuration options.
You may be able to also use the boards by selecting the Release 13 for
DOS Accelerated Display Drivers VESA mode. Image Processing Systems
provides an Release 13 compatible ADI 4.2 driver with their OverView
series of adapters. Contact the manufacturer for more details.

Matrox
HiPER VGA               S3 Inc.             86C911
HiPer +                 S3 Inc.             86C924
Illuminator (*)         Matrox              Custom
Illuminator-PRO (*)     Matrox              Custom
Impression 1024         S3 Inc.             86C924
MG-104                  Western Digital     WD95C00
MG-108                  Western Digital     WD95C00
MG-124                  Western Digital     WD95C01
MG-128                  Western Digital     WD95C01
MG-3D (!)               Matrox              Custom
MG-3D Ultra (!)         Matrox              Custom
MGA Impression (!)      Matrox              MGA
MGA Impression Plus (!) Matrox              MGA II (64)
MGA PCI 2+ (!)          Matrox              MGA II (64)
MGA Ultima Plus         Matrox              MGA II (64)
(PCI/VL) (!)
MGA PCI 2+ (!)          Matrox              MGA II (64)
PG-640 (!)              Hitachi             HD63484
PG-1281 (!)             TI/Matrox           34010/Custom
SM-640 (!)              Hitachi             HD63484
SM-1280 (!)             Hitachi             HD63484

The DOS ADI 4.2 Accelerated Display List Driver supplied with AutoCAD
Release 13 provides support for some Matrox graphics accelerators. Use
the S3 configuration option for the HiPER series and Impression 1024.
The MG-1xx series should be configured using the Western Digital
WD95C00 selection.

Matrox graphics boards using the MGA, HD63484, TI34010 or custom
processors are not supported by the Release 13 supplied Accelerated
Display Driver. Matrox offers their high performance DynaView ADI 4.2
driver for use with AutoCAD Release 13. Please contact Matrox for more
information.

Maxlogic
MaxVGA/16 (*)           Western Digital      PVGA-1A
MaxVGA/1024 (*)         Western Digital      PVGA-1A

Configure AutoCAD's Release 13 Accelerated Display Driver for VGA when
using the Maxlogic MaxVGA series of graphics adapters. For higher
resolution or color depth support, please contact the manufacturer for
information on obtaining an ADI 4.2 driver.

Metheus
Premier                 Chips & Tech         82C452
Premier 1meg            Tseng Labs           ET4000AX
Premier 801             S3 Inc.              86C801
Premier 928             S3 Inc.              86C928
Premier 928-VL2         S3 Inc.              86C928
Premier 928-VL4         S3 Inc.              86C928
Premier HiColor         Tseng Labs           ET4000AX
Premier S3              S3 Inc.              86C911
UGA 1104(!)             Metheus              Omega
UGA 1104 Plus (!)       Metheus              Omega
UGA 1124, 1128 (!)      Metheus              Omega
UGA 1224, 1228 (!)      Metheus              Omega

Autodesk's Accelerated Display Driver for AutoCAD Release 13 supports
most Metheus graphics controllers which do not use proprietary video
processors. The Premier 1meg and HiColor cards should be configured
using the Tseng Labs ET4000 processor selection. Metheus' Premier S3,
801 and 928 series should use the appropriate S3 chip configuration
option.

The Metheus line of Ultra Graphics Accelerators (UGA) utilizes a
proprietary graphics processor which is not supported by the AutoCAD
for DOS Release 13 supplied Accelerated Display Driver. Metheus offers
AutoPlus, a high performance ADI 4.2 display list driver which
supports AutoCAD Release 13. Contact Metheus (503-690-1550) for
information on how to obtain this driver.

miro Computer Products
miroCRYSTAL 16Si VLB    S3, Inc.            86C805i
miroCRYSTAL 20PV (!)    Weitek              P9100
miroCRYSTAL 20SD (*)    S3, Inc.            86C864
miroCRYSTAL 20SV (*)    S3, Inc.            86C964
miroCRYSTAL 20TD (*)    Tseng Labs          ET4000/W32p
miroCRYSTAL 32S VLB     S3, Inc.            86C928
miroCRYSTAL 40PV (!)    Weitek              P9100

Many of miro's line of miroCRYSTAL graphics cards utilize popular
graphics accelerator chips which are supported by AutoCAD for DOS's
Release 13 Accelerated Display Driver. The 16Si and 32S VLB cards
should be configured using the appropriate S3 chip set option.

The miroCRYSTAL 20PV, 20SD, 20SV, 20TD and 40PV may function when the
Accelerated Display Driver is configured for VESA. These cards may
also operate when choosing the S3, Tseng or Weitek processor (see
above listing) options, but such configurations are not supported.
miro Computer Products does offer high performance DOS ADI 4.2 drivers
for most of their video cards. Contact miro for details.

Nanao
HA 50, HA 50 VL         S3, Inc.            86C928
HA 60                   S3, Inc.            86C928

Use the S3 928 option when configuring for the Nanao HA 50 and 60
series of graphics accelerators.

National Design, Inc. (Volante)
AT600                   S3, Inc.            86C911
AT600PLUS               S3, Inc.            86C924
AT800 (!)               Texas Instruments   34020
Volante AT1000 (!)      Texas Instruments   34020
Volante AT1200 (!)      Texas Instruments   34020
Volante AT1600 (!)      Texas Instruments   34020
Volante AT2000 (!)      Texas Instruments   34020
Volante MC1000 (!)      Texas Instruments   34020
WARP10/WARP10PLUS       S3, Inc.            86C801
WARP10/LB, LB-2         S3, Inc.            86C805

The NDI Volante AT600, AT600PLUS, WARP10, WARP10PLUS and WARP10/LB are
all supported via the S3 chipset selection. Use the S3 911/924/928
option for the AT600 series and the 801/805 choice for the WARP10
series.

The Volante AT800, AT1000, AT1200, AT1600, AT2000 and MC1000 use the
TI 34020 processor, which is unsupported by the AutoCAD Release 13 DOS
Accelerated Display Driver. DOS ADI 4.2 TIGA drivers are available
from a number of Registered ADI Driver Developers. Volante also
provides a high performance ADI 4.2 DOS display list driver for their
video cards. Contact Volante for more information on obtaining this
driver.

NEC
MVA 1024 (!)            Texas Instruments   34010
Multisync Graphics      Texas Instruments   34010
Engine (!)

The NEC video cards use the TI 34010 processor which is unsupported by
the AutoCAD Release 13 DOS Accelerated Display Driver. DOS ADI 4.2
TIGA drivers are available from a number of Registered ADI Driver
Developers which may support the NEC graphics boards.

Nth Graphics
Nth 150 (*)             Chips & Tech        82C480
Nth Engine (!)          Inmos               Transputer
Nth Engine/124          Tseng Labs, Inc.    ET4000
Nth Edge 1280           Chips & Tech        82C481
S3 Advantage            S3, Inc.            86C801

The Accelerated Display Driver supports the Nth Engine/124 via the
Tseng Labs ET4000 option. Nth's S3 Advantage should be configured
using S3 801/805 chip set selection.

Partial support may exist for the Nth 150 by using the Chips and
Technologies 82C480 chip menu pick. The Nth Engine uses a proprietary
graphics processor which is unsupported by Accelerated Display Driver.
ADI 4.2 DOS drivers may be available from Nth Graphics. Please contact
them for more information.

Number Nine Computer Products
#9GXE (Levels 1, 2, 3)  S3, Inc.            86C928
#9GXE 4MB               S3, Inc.            86C928
#9GXE 1600              S3, Inc.            86C928
#9GXi (!)               Texas Instruments   34020
#9GXE64 (*)             S3, Inc.            86C864
FlashPoint 64 (*)       Cirrus Logic        GD5434

Many of the Number Nine graphics cards are compatible with AutoCAD
Release 13's supplied DOS Accelerated Display Driver. Configure the
#9GXE series using the S3 911/924/928 option. Partial functionality
may exist for the #9GXE64 under the S3 801/805 choice and for the
FlashPoint 64 using the Cirrus GD542x menu selection, but use of the
VESA pick may prove more reliable.

Oak Technology
37                      Oak Technology      OTI-037
67                      Oak Technology      OTI-067
77                      Oak Technology      OTI-077

Use the Oak OTI-0x7 selection for the above video cards.

Orchid Technology
Celsius                 Weitek              Power9000
Fahrenheit 1280(v1&2)   S3 Inc.             86C911
Fahrenheit 1280(v3)     S3 Inc.             86C924
Fahrenheit 1280 Plus    S3 Inc.             86C801/805
Fahrenheit VA           S3 Inc.             86C801
Fahrenheit VA-LB        S3 Inc.             86C805
Fahrenheit 64 (!)       S3 Inc.             86C864
Fahrenheit Pro 64 (!)   S3 Inc.             86C964
Orchid P9000 VLB        Weitek              Power9000
Kelvin 64 (*)           Cirrus Logic        5434
Pro Designer            Tseng Labs          ET3000
Pro Designer 800        Tseng Labs          ET3000
Pro Designer II         Tseng Labs          ET4000AX
Pro Designer IIs        Tseng Labs          ET4000AX
Pro Designer Plus       Tseng Labs          ET3000

The Accelerated Display Driver for AutoCAD Release 13 provides support
for many Orchid Technology graphics boards. Use the Weitek P9000
selection for the Celsius or Orchid P9000 VLB accelerator cards.
Fahrenheit 1280 cards should use the S3 911/924/928 option, while the
Fahrenheit VA and Plus series operate with the S3 801/805 menu pick.
Configure the Pro Designer series with the appropriate Tseng Labs chip
selection.

Orchid's Kelvin 64 may operate under the Cirrus GD542x option, but
using the VESA configuration is preferred. The Fahrenheit 64 and Pro
64 should be configured using the VESA option as well. Orchid
Technology also provides high performance ADI 4.2 drivers for DOS
AutoCAD Release 13. Contact Orchid for more details.

Paradise
Accelerator 24          Western Digital     WD90C31
Accelerator Pro (!)     IIT                 AGX-014
Accelerator VL Plus     Western Digital     WD90C33
Accelerator/Ports       Western Digital     WD90C33
O'Call
Paradise 8514/A Plus    Western Digital     WD95C00
Paradise Super VGA      Western Digital     WD90C30
Paradise Value Card     Oak Technology      OTI-077
VGA 1024                Western Digital     WD90C00
VGA Professional (*)    Western Digital     PVGA-1A
Windows Accelerator     Western Digital     WD90C31

Most of the Paradise graphics cards are supported by the Release 13
for DOS Accelerated Display Driver. Utilize the appropriate graphics
processor configuration option by referring to the above list.

The AGX-014 based Accelerator Pro is not directly supported for the
Release 13 DOS Accelerated Display Driver. The card may function in
XGA mode, but Autodesk recommends using the VESA compatible selection
of our driver for initial configuration. Paradise's VGA Professional
should function as a standard VGA although extended functionality will
not be available in this mode. Paradise supplies high performance DOS
(P386) ADI 4.2 drivers which support AutoCAD Release 13 for most of
their video cards. Contact Paradise (800-832-4778) for more
information about their AutoCAD Release drivers.

Personal Computer Graphics Corp (PCG)
70/70Deluxe             S3, Inc.            86C924
Performa (*)            Chips & Tech        82C451
Photon FX50CL.          Cirrus Logic        542x
Photon GXA9000          Weitek              Power 9000
Photon Viper 1280/70    Chips & Tech        82C480
(*)
Photon XV20             Chips & Tech        82C452
Torpedo 564 (*)         Cirrus Logic        543x
Torpedo 80x             S3, Inc.            86C801/05
Torpedo 864 (*)         S3, Inc.            86C864
UltimaTurbo             Trident             8900

PCG's 70/70 Deluxe, Photon FX50CL, Photon GXA9000, Photon XV20,
Torpedo 800 series and UltimaTurbo should be fully compatible with the
Release 13 for DOS Accelerated Display Driver. Select the appropriate
graphics processor configuration option from the above listing.

The Photon Performa and Performa Turbo should be compatible with the
DOS Accelerated Display Driver's C&T 82C452 configuration option. Not
all resolutions or color depths supported by the 452 chip will
function on 451 based video cards. The Photon Viper 1280/70 will
operate by selecting the 8514/A mode and potentially may be configured
by using the C&T 82C481 graphics chip menu choice.

PCG does offer AutoCAD Release 13 ADI 4.2 drivers for use with the
majority of their graphics accelerators. Please contact the
manufacturer for information on obtaining current driver versions.

Pixelworks
Clipper (!)             Fairchild          Clipper
UltraClipper (!)        Fairchild          Clipper
WhirlWIN (*)            Chips & Tech       82C480
WhirlWIN Lite           S3, Inc.           86C911
WhirlWIN Plus           Chips & Tech       82C481

AutoCAD Release 13's supplied DOS Accelerated Display Driver will
function with the Pixelworks line WhirlWIN of graphics controllers as
documented above. Configure the WhirlWIN by selecting either the IBM
8514/A or C&T 82C481 options.

The Pixelworks Clipper and UltraClipper cards implement an unsupported
proprietary processor. For Release 13 driver support, contact the
manufacturer.

Prism
EXCELSIOR               Tseng Labs         ET4000
Prism VGA               Tseng Labs         ET4000
VGA/Eclipse             Tseng Labs         ET4000

The Prism VGA and SVGA cards noted above are to be configured using
the Tseng Labs ET4000 option of the DOS Accelerated Display Driver.

Rasterex (Expert Graphics)
Lazer Series (!)        Texas Instruments   34010
Liberty Series (!)      Texas Instruments   34010
Tracer 1280  (!)        Texas Instruments   34020

The Rasterex Lazer series, Liberty series, and Tracer 1280 are not
supported with the Release 13 Accelerated Display Driver. Rasterex
provides a high performance display list driver for use with AutoCAD
Release 13. Please contact the manufacturer for information on
obtaining this DOS ADI 4.2 driver. As an alternative, there are a
number of Registered ADI Driver Developers who develop TIGA based ADI
4.2 drivers which may support the Rasterex boards.

RasterOps
ColorImpact 100 (*)     Cirrus Logic        GD5434
ColorImpact Pro 1000    Weitek              P9100
(!)

The RasterOps ColorImpact cards are only supported by AutoCAD Release
13 by using the VESA configuration. Contact RasterOps regarding
obtaining DOS (P386) ADI 4.2 drivers for Release 13 AutoCAD.

Sigma Designs
VGA Legend              Tseng Labs          ET4000AX
VGA Legend II           Tseng Labs          ET4000AX

The Sigma Designs VGA Legend series of ET4000 based graphics cards is
supported by AutoCAD Release 13. Use the appropriate option as
indicated above.

Software Integrators
Mercury X1              S3, Inc.            86C801
Mercury X1VL            S3, Inc.            86C805i
Mercury X2 (!)          S3, Inc.            86C864/964

Software Integrator's Mercury X1 cards are supported by AutoCAD
Release 13. Use the S3 801/805 configuration selection for these
boards. The X2 cards are not directly compatible with the S3 selection
but should operate under the VESA selection.

Spea
Fire (!)                Intel               i860

No support is offered for i860 based cards such as the Spea Fire.
Please consult the manufacturer for details on obtaining an ADI 4.2
driver.

STB Systems
AutoVGA (*)             Cirrus Logic        GD510/520
EM+ Powergraph          Tseng Labs          ET4000AX
ERGO                    Tseng Labs          ET4000AX
Horizon                 Cirrus Logic        GD5426
MVP                     Tseng Labs          ET4000
Nitro ISA (*)           Cirrus Logic        GD5430
Nitro PCI (*)           Cirrus Logic        GD5434
Pegasus                 S3, Inc.            86C928
Powergraph VL-24        S3, Inc.            86C805
Powergraph X-24         S3, Inc.            86C801
Powergraph Pro PCI (!)  S3, Inc.            86C864
VGA 800/16 (*)          Chips & Tech        82C451

Select the Tseng Labs ET4000 to configure for the EM+ Powergraph, the
ERGO and MVP cards. STB's Horizon uses the Cirrus GD5426 chip
selection, while the Pegasus, Powergraph VL-24, and X- 24 use the S3
chipset 801/805 menu pick.

The STB VGA 800/16 should be compatible with the Accelerated Display
Driver's C&T 82C452 configuration option. Not all resolutions or color
depths supported by the 452 chip will function on 451 based video
cards. Use the VGA config option for STB's AutoVGA. For the Powergraph
Pro PCI and Nitro series of graphics accelerators, we recommend using
the VESA selection. Additionally, STB offers high performance ADI
display list drivers for use with most of their graphics cards. Please
contact STB Systems for information on obtaining current driver
versions.

Tecmar
9400 (*)                Trident              9400
VGA/AD                  Tseng Labs           ET-3000

Use the Tseng Labs graphics chip configuration option for the Tecmar
VGA/AD series of video adapters. The Tecmar 9400 will function with
either the Trident 8900 or VESA selections. As not all resolutions or
color depths supported by the 9400 chip will function with the 8900
choice, Autodesk recommends use of the VESA selection.

Trident
8900CL/D                Trident              8900
9000 (*)                Trident              9000
9400 (*)                Trident              9400
9400 CXI (*)            Trident              9400
TVGA 8816 (*)           Trident              8800
TVGA 8916               Trident              8900
ImpactII (*)            Trident              9000
ImpactIII (*)           Trident              9000

Autodesk's support for Trident cards is handled through the Trident
8900 graphics processor menu option. Most newer Trident chips (9000,
9400) and the cards that use them are fully backwards compatible with
the 8900 series. Trident also provides an ADI 4.2 display list driver
with their cards. Contact Trident for information on how to obtain
this driver.

Truevision, Inc.
Color Impact 100 (*)    Cirrus Logic         GD5434
Color Impact Pro 1000   Weitek               P9100
(!)
Video Impact 100 (*)    Cirrus Logic         GD5434
Video VGA 8             Tseng Labs           ET4000AX
Video VGA 16            Tseng Labs           ET4000AX

Truevision's Video VGA series are configured for use with AutoCAD
Release 13 for DOS by selecting the Tseng Labs ET4000 chip option. The
Color Impact 100 and Video Impact 100 are backwards compatible with
Cirrus GD542x chip configuration menu selection and may operate with
limited resolution and color depth support. For proper operation, the
Color Impact, Color Impact Pro, and Video Impact should use the VESA
selection.

Vibrant Graphics
Vanguard                Chips & Tech         82C481

Use the C&T 82C481 processor selection when configuring the AutoCAD
Release 13 for DOS supplied Accelerated Display Driver.

Video 7
1024i                   Headland Tech        HT208
FastWrite               Headland Tech        HT205
VEGA VGA (*)            Cirrus Logic         GD410/420
V-RAM                   Headland Tech        HT205
V-RAM II                Headland Tech        HT209
WIN.VGA (*)             Headland Tech        HT216

Configure the VEGA VGA by choosing the IBM VGA selection. For the
WIN.VGA, choose either VESA processor option. All other Video Seven
cards listed above are directly supported.

VidTech MicroSystems
FastMax P20 (!)         S3, Inc.             86C864
GraphMax (!)            IIT                  AGX-014
GraphMax LB (!)         IIT                  AGX-015

As none of the graphics processors used by the VidTech cards are
directly supported by the supplied AutoCAD Release 13 for DOS
Accelerated Display Driver, Autodesk recommends using the VESA
configuration option. VidTech also provides high performance ADI 4.2
drivers for use with AutoCAD Release 13. Contact VidTech for more
details regarding obtaining their most current drivers.

VMI
Cobra (!)               Texas Instruments   34010
Cobra Plus (!)          Texas Instruments   34020
DesignMaster VGA        Tseng Labs          ET4000
DesignMaster S3-805-    S3, Inc.            86C805
VLB
X Series (!)            VMI                 Custom

The VMI DesignMaster VGA should function if configured using the DOS
Accelerated Display Driver Tseng Labs ET4000 option. Use DOS AutoCAD
Release 13 for DOS 's supplied driver S3 801/805 chip set option to
support the DesignMaster S3-805-VLB.

The Cobra and X series of video adapters are not supported by the
Release 13 Accelerated Display Driver. Please contact the manufacturer
for information on obtaining a DOS ADI 4.2 driver. As an alternative,
there are a number of Registered ADI Driver Developers who develop
TIGA based ADI 4.2 drivers which may support the Cobra boards.


Digitizer Drivers (DOS)
=======================-


DOS Dialog Boxes
----------------
Dialog boxes in AutoCAD for DOS use the digitizer as a mouse,
bypassing the tablet button menu lookup. Therefore, pressing the
digitizer return key (usually the 2nd physical button) will not close
the dialog box.


=====================================================================-
NETWORK AND HARDWARE LOCK INFORMATION FOR PCS
=============================================-


This information supplements the AutoCAD Release 13 Installation
Guide. Because of the continued testing that has taken place after
printing of the manuals, there is additional network information
contained in this document. Therefore, it is recommended that you read
this document before installing and configuring Release 13 for
networks.

  - Hardware Lock Compatibility Issues
  - Novell Netware Client Software
  - SERVER System Variable

Hardware Lock Compatibility Issues
==================================-
The Rainbow hardware lock will work with IEEE 1284 compliant devices.
If non-conforming devices are connected to the hardware lock, it is
possible that they may not function properly. Some of the devices that
may cause problems include:

+   Older Traveling Software LapLink file transfer cable
+   Flying Dutchman file transfer cable
+   SCSI adapters
+   Ethernet adapters

If you are having problems with one of these devices, it is
recommended that you either remove the hardware lock from the cable or
connect the device to a separate parallel port as a possible solution.

Novell Netware Client Software
==============================-


Novell Netware 3.X Client Software
-----------------------------------
If you are a user on a Novell Netware Client using Version 3.X, you
should have at least read, write, and create rights (permissions)
setup in your drawing directories.

However, if the parent directory for your drawing directory does not
have create right specified, when you access the Open File dialog box,
the Read Only box will be checked. To be able to update your drawing
and write your updates to your drawing directory, you must de-select
this Read Only box.

Alternatively, you may want to upgrade your Novell Netware Server to
the most current software version (4.X).


Novell Netware 4 Client Software
--------------------------------
AutoCAD Release 13 users who use Novell Netware 4 Client Software
(VLM.EXE) must use Version 1.10 of the VLM files. Version 1.03 is
currently delivered with Netware Versions 4.0 and 3.12. The user can
get the following upgrade file from CompuServe: dosup9.exe.


SERVER System Variable
======================-
Prior to Release 13, the SERVER system variable indicated the number
of logged in users per the ACAD.PWD file. With the removal of ACAD.PWD
in Release 13, the number of authorized users is managed by the
AutoCAD network license server. For compatibility purposes, this
system variable is set to "1" on a networked system, and "0" on a
single-user system.


=====================================================================-
WINDOWS-SPECIFIC NETWORK INFORMATION
====================================-

  - Using Windows NT Clients with Novell Netware Servers
  - Windows NT and Windows 95 Network License Server


Using Windows NT Clients with Novell Netware Servers
====================================================-
Under some circumstances, AutoCAD drawing files that are written from
an NT workstation to a Novell Netware file server can open in read-
only mode for NT workstations. We found that upgrading to the latest
network software will remedy this. If this is a problem for you, we
recommend the following three steps.

+   Install/upgrade to the latest Microsoft NT Service Pack.
+   Install/upgrade to the latest Novell Netware client for NT and
    the first clause. Note, the order of these first 2 steps is
    important, i.e, do the Microsoft NT Service Pack upgrade before
    upgrading the Novell Netware client.
+   Also install the most current Novell Netware file server NLM
    updates.

Also be sure that read/write access has been assigned to the
directory. The Novell utility "Rights" can be used to check the
read/write permissions. Note that only the Novell File Server
administrator, via the system console utility, can be used to set
permissions.


Windows NT and Windows 95 Network License Server
=================================================-
A new unified version 4.40 network license server supports both NT and
Windows 95 platforms (NSRVGX.EXE). The new license server no longer
requires the IPX SAP Agent service for proper operation as in the
previous version. This provides a more consistent network connection
for the IPX protocol. If upgrading to this new server, you may elect
to remove this service if other application requires this. Windows NT
platforms upgrading to the new server will require you also upgrade
the Sentinel system driver. There are two ways to accomplish this:

+   Manually re-install the Sentinel driver as described in the
    Installation Guide.
+   Use the new Sentinel driver installer application


Installing the Windows NT Sentinel System Driver
------------------------------------------------
To install or upgrade the NT Sentinel driver using the new driver
installer application, run the install batch file, INSTALL.BAT, from
the AutoCAD driver directory: \R13\WIN\DRV\NTLOCK.  You can run this
either from a DOS shell or from RUN via the File Menu.  Then follow
these steps:

1.  A window with the title bar "Sentinel Driver Setup Program" is
    displayed.
2.  Select "Functions" and then "Install Sentinel Driver" from the
    menu bar.
3.  A dialog box with the default path for the NT driver is
    displayed.  Change the path if        necessary and click "OK".
4.  The Sentinel Driver and associated files are copied to the hard
    disk.  One of the DLLs, SNTI386.DLL, SNTMIPS.DLL, SNTALPHA.DLL,
    or SNTPPC.DLL and SENTTEMP.HLP are copied to
    \%SYSTEMROOT%\SYSTEM32. SENTTEMP.SYS is copied to the file
    \%SYSTEMROOT%\SYSTEM32\DRIVERS\SENTINEL.SYS.  %SYSTEMROOT% is the
    directory where Microsoft Windows NT has been installed.
5.  If the driver installation is successful, a dialog box with the
    message "Sentinel Driver Files Copied Successfully" is displayed.
6.  When complete, a dialog box with the message "Driver Installed!
    Restart your system" is displayed.
7.  Click "OK" to continue.
8.  Restart your computer.

If you need to configure a special(non-standard) I/O port, from step 2
select the "Configure Sentinel Driver" menu item instead.


Installing the Windows 95 Sentinel System Driver
------------------------------------------------
Install the Win95 Sentinel system driver if you plan to run a Win95
license server (NSRVGX.EXE).  To install Sentinel driver VXD, change
over to the AutoCAD Win95 driver directory (\R13\WIN\DRV\W95LOCK) and
run the SENTW95.EXE from a DOS shell or from the Start/Run Button.

1.  A window with the title bar "Sentinel Driver Setup Program" is
    displayed.
2.  Select "Functions" and then "Install Sentinel Driver" from the
    menu bar.
3.  A dialog box with the default path for the driver is displayed.
    Change the path if        necessary and click "OK".
4.  When complete, a dialog box with the message "Driver Installed!
    Restart your system" is displayed.

If you need to configure a special(non-standard) I/O port, from step 2
select the "Configure Sentinel Driver" menu item instead.  You can
also uninstall the Sentinel driver by selecting the "Remove Sentinel
Driver"  menu item from step 2.  Be sure to restart your system to
allow the system driver to properly load.  Once the Sentinel driver is
loaded, you can now start the license server.

The multi-protocol license server, NSRVGX.EXE, has additional command
option switches to aid in diagnosing network protocol access problems.
The following switches are:

/SN:0          Disables license grants from the NetBios/NetBeui
               protocol
/SW:0          Disables license grants from the IPX protocol

Note:  It has been determined that the Win95 license server with the
August 95 release of Win95 may exhibit network license connection
problems with the IPX protocol.  A revised version of the Win95
winsock.dll file is needed to correct the problem properly.
Microsoft, some time in the near future, will make this available via
their normal updates.  This only affects the IPX network protocol.  If
you use the default NetBios/NetBeui protocol, no problems have been
found with regard to the license server.


=====================================================================-
DOS-SPECIFIC NETWORK AND HARDWARE LOCK INFORMATION
==================================================-

  - New IPX Network Protocol DOS License Servers
  - Using the DOSMON Monitor Program


New IPX Network Protocol DOS License Servers
=============================================-
New IPX network protocol DOS license servers have been provided:

+   Novell Server NLM:  NSRVNI.NLM
+   DOS TSR Server:  NSRVDI.EXE

Update your system with these servers if they apply for proper
operation.


Using the DOSMON Monitor Program
================================-
The NetSentinel monitor displays information on all security servers
and NetSentinel keys in the network. This information includes the
server transport protocols, number of licenses in use, number of users
who were disconnected after timing out, and license limit for each
key.

The DOSMON monitor program is designed for DOS users who use a license
server as a TSR program. To use the DOSMON monitor program, follow
these guidelines:

1.  Use the arrow keys and press ENTER to highlight a selection.
2.  To return to the previous screen, press ESC. (Pressing ESC from
    the first screen exits the program.)
3.  For help on any screen, press F1.
4.  The monitor will recognize a mouse. On menus, a single click
    moves the highlight bar, and a single click on the highlight bar
    selects the menu option.


Starting the DOSMON Monitor
---------------------------
Before running the DOSMON monitor, start the appropriate network
transports (IPX/SPX or NetBIOS). Usually the NetSentinel monitor
automatically detects the type of display you are using. However, if a
monochrome display is used with a color card, the NetSentinel monitor
may detect a color display. To override automatic display sensing, do
one of the following prior to starting the monitor:

+   For a monochrome display, set the environment variable PNLMONO to
    "1".
+   For a color display, set the environment variable PNLCOLOR to
    "1".

To start the monitor, enter DOSMON and press ENTER. The monitor scans
the network for NetSentinel keys and displays an interactive menu to
display the findings. Move the highlight bar to the desired selection
and press ENTER.


Display All Security Servers
----------------------------
To display all security servers connected to your network, select
"View by Server" from the Network Monitor Main menu. You are provided
with a list of servers on the network, the versions of each server,
the number of NetSentinel keys currently connected to each server, the
security server transport mechanism (protocol), and the network node
address for each server.


Display All Algorithms
----------------------
To display all NetSentinel developer/algorithm identifiers on your
network, select "View by Algorithm" from the Network Monitor Main
menu. You are provided with a list of all NetSentinel algorithms and
developer IDs on the network, the number of NetSentinel keys on your
network that have this identifier, the total licensing limit for all
of these keys, the number of licenses that are currently in use for
this identifier, the number of licenses that are timed-out and were
disconnected since the server was executed, and the greatest number of
licenses for this identifier that have been in use at any one time.


Display All Keys on a Server
----------------------------
To display all keys managed by a specific security server, select
"View by Server" from the Network Monitor Main menu. You are provided
with a list of the algorithm identifiers assigned to the current key,
the maximum number of concurrent users allowed by this key, number of
licenses in use on this key, the number of licenses on this key that
timed-out and were disconnected since the server program was executed,
the greatest number of licenses for this key that have been in use at
any one time, and whether or not the key is currently locked against
queries.


Display All Keys with a Given Algorithm
---------------------------------------
To display all keys with a specific algorithm, select "View by
Algorithm" from the Network Monitor Main menu. You are provided with a
list of the names of the security servers, the maximum number of
concurrent users allowed by this key, the number of licenses currently
in use on this key, the number of licenses on this key that timed-out
and were disconnected since the server program was executed, the
greatest number of licenses for this key that have been in use at any
one time, whether or not the key is currently locked against queries,
and the security server transport mechanism.


Printing the Network Configuration
----------------------------------
To print the network configuration to a printer, select the "Print
Network Database" option from the Network Monitor Main menu, then
select "Print to the Printer". To print the network configuration to a
file, select "Print to File" from the Select Print option list.


Displaying and Changing Department Names
----------------------------------------
To display or change department names, select "Display Department
Names" from the Network Monitor Main menu. Use the TAB key to scan the
network for additional servers attached to the department names you
assign.


DOSMON Command Line Options
---------------------------
The following command line options are supported by the DOS monitor.

Option         Description
------------   -----------------------------------------------------
/DN:<name>     Changes the server's department name from NETINEL to
               <name>. Clients must use the Set Rainbow Library
               Parameters API call to access servers with department
               names other than NETINEL.
/H /?          Displays help information on the console. Output can be
               redirected to a file using >.
/I             Searches for security server using the IPX/SPX
               protocol.
/MS:<nnn>      Sets the maximum number of servers running on the
               network to <nnn>. The value ranges from 1 to 10 and is
               used to determine the range of server names.
/N             Searches for security servers using NetBIOS protocol.
/S             Displays software security information (network license
               configuration and status) on the console, and then
               terminates. Output can be redirected to a file using "
               >."