                      Using SWTEST and BIOSDUMP
                      -------------------------

              Copyright 1991 by Phar Lap Software, Inc.


                                SWTEST
                                ------

    SWTEST is a diagnostic program used for testing the
protected/real mode and A20 switching methods used by
286|DOS-Extender. It is linked with the same mode-switching code as
286|DOS-Extender, and can also load and run an external SWITCH.BIN
file (see the 286|DOS-Extender -SWITCH switch, described in the
document DOSX.TXT). The results of SWTEST can be sent to your
applications developer or technical-support staff.

    SWTEST can be run so that it simply outputs its results to the
display, or it can run in an interactive mode, where user and machine
information is interrogated and output to the SWTEST.OUT file along
with the test results. When outputing to the SWTEST.OUT file, the
file is opened in append mode so that any old information will be
preserved. This allows easy testing of multiple machines by running
the SWTEST program from a floppy disk (and writing the SWTEST.OUT
file to the floppy). An additional file named SWTEST.INF is created
and updated to save user and machine information for subsequent
tests.

    SWTEST reports the following information:

(1)  The version of SWTEST and of the switch code.
(2)  The BIOS "signature," a 32-bit checksum of selected portions of the
     BIOS ROM.
(3)  The date of the BIOS, if found in the location where the IBM PC 
     stores its BIOS date.
(4)  The Machine ID, a number which results from the identification of 
     individual machines based on the BIOS signature or other techniques. 
     A Machine ID of zero indicates that the individual machine could
     not be identified.
(5)  The A20 switch method name and number.
(6)  The Reset method name and number.
(7)  The Protected/Real Mode switch method name and number.
(8)  The average, minimum, and maximum times (in microseconds) to switch
     to protected mode, switch back to real mode, and the combined totals.

    A number of options can be selected on the command line. Each
option must start with a '/', and the options must each be separated
by at least one space. The available options are:

/h   = print out help information (don't run any tests)
/s## = use switch method number ##
/a## = use A20 method number ##
/r## = use reset method number ##
/n## = run ## test passes before reporting results (default is 1000 passes)
/f## = set switch flags to ##
/x   = use external switch.bin file
/i   = create SWTEST.INF file if it does not exist
/d   = output test results to display only

    For example, the command line:

swtest /s2 /a1 /i

would use switch method number 2, A20 method number 1, and a
SWTEST.INF file to be created if it didn't already exist.

    If any of the method numbers are not given, the switch routines
will determine a default method to use. The general intention is that
appropriate method numbers will be chosen based on the machine ID or
other identifying factors.

    If neither the /i nor /d option is given, then the existence of
the SWTEST.INF file will determine whether or not user and machine
information is interrogated and output is written to the switch.out
file. If the /i option is given, then the SWTEST.INF will be created
if it doesn't already exist, and data will be always be written to
the swtest.out file. If the /d option is given, then nothing will be
output to the SWTEST.OUT file, even if the SWTEST.INF file already
exists.

    The current mode switch method numbers are:
    
1 = SURE
2 = AT
3 = SLOW
4 = VCPI
5 = 386

    The current A20 switch method numbers are:

1 = AT
2 = PS2
3 = VECTRA
4 = 6300
5 = XMS
6 = ACER
7 = ZENITH
8 = NEAT
9 = PHOENIX
10 = TOSHIBA
11 = WYSE

    The current reset method numbers are:

1 = STANDARD
2 = 8042

    It is possible to control certain operations with the switch
flags. Each flag is a bit of the flags word, and multiple flags can
be specified by adding their values together.  The /f## command
option is used to set the flags, and the flags value is given as a
decimal (base 10) number.  The current switch flags are:

1 = Skip test for AT method.  Normally, if the machine cannot be
    identified through the internal machine table, an attempt is made
    during initialization to try the AT switching method, checking for a
    reprogramming of the 8259 interrupt controllers and whether the BIOS
    enables interrupts when switching.  This flag skips this test and
    just chooses the SURE switch method, which is generally slower than
    the AT method.  
2 = Unused.  
4 = Force A20 to be disabled whenever entering real mode.  Some mode
    switch methods normally enable the A20 line during initialization and
    leave it enabled throughout execution.  This flag causes the A20 line
    to be disabled on every switch to real mode, and to be re-enabled on
    every switch to protected mode.

    The results of running SWTEST should be sent to your applications
developer or technical-support staff.


                               BIOSDUMP
                               --------

    BIOSDUMP can be used in case of serious mode-switching problems.
Running BIOSDUMP.EXE creates a 64k file, BIOS.OUT, which contains an
image of your ROM BIOS. The file BIOS.OUT can be sent to your
applications developer.

                               - END -