                           Tape Device Drivers

        Gazelle Systems' Back-It 4 and Back-It 4 LAN currently includes
        six different tape device drivers.  This text file describes
        each device driver and the hardware manufacturers' tape devices
        supported.  Hardware specific information required to configure
        the device by the program BKUTIL is also described.  We suggest
        that you consult the tape manufacturer's documentation and look
        at your hardware settings before running BKUTIL.


        
        Device name:        	AIWAQ80.GSD

        Format:             	QIC 80

        Manufacturers:      	Aiwa TD-803, and TD-811 drives

        Hardware information required to configure device:
             Data Transfer Rate       	500K bps 

             
             
        Device name:        	COLORADO.GSD

        Format:             	QIC 40

        Manufacturers:      	Colorado Memory Systems, Tall Grass,
                                some Mountian drives.

        Hardware information required to configure device:
             Controller Port Address    3F0 (default), user selected
             IRQ Interrupt Number       IRQ3, IRQ4, IRQ5, IRQ6(default), IRQ7
             DMA Channel Number       	Channel 1, 2 (default), or 3
             Is an (AB 10) adapter card being used?   YES or NO



        Device name:        	COLORAD2.GSD

        Format:             	QIC 40

        Manufacturers:      	Colorado Memory Systems newer drives.
                                Often these drives have a 120 MB on the
                                face plate. If you look on the back or
                                top of the drive you will see a white label.
                                If this label states that the F.W. (Firmware)
                                revision is 40 or higher this is the correct
                                driver for your system.
                                NOTE: We are not compatible with Colorardo's
                                Hardware compression cards.

        Hardware information required to configure device:
             Controller Port Address    3F0(default), user selected
             IRQ Interrupt Number       IRQ3, IRQ4, IRQ5, IRQ6(default), IRQ7
             DMA Channel Number       	Channel 1, 2 (default), or 3
             Is an (AB 10) adapter card being used?   YES or NO




        Device name:        	EVERX36.GSD

        Format:             	QIC 36

        Manufacturers:      	EVEREX 831 CONTROLLER with any QIC 36 drive,
                       		e.g., Cipher, CMS Enhancements, Mountain,
                       		Tallgrass, and Wangtek.

        Hardware information required to configure device:
             Drive Number             	0 (default), 1, 2, or 3
             Controller Port Address    370 (default), user selected
             Interrupt Channel        	IRQ3 (default), IRQ4, IRQ5, IRQ6, IRQ7
             DMA Channel Number      	Channel 1 (default), 2, or 3




        Device name:        	GENDAT.GSD

        Format:             	SCSI DAT/8MM

        Manufacturers:      	Most DAT and Exabyte 8200/8500  drives on an
                                Adaptec, Western Digital WD7000 SCSI, Allways
                                IN2000,Bitech 21xx, Sumo, or most Future
                                Domain SCSI boards.

        Hardware information required to configure device:
             SCSI Unit Number     Unit: 0, 1, 2, 3, 4, 5, 6, 7, auto (default)
             Host Adapter          Auto, Adaptec, WD/TNT, IN2000, Bitech 21xx
                                         Sumo, Future Domain


             
        Device name:        	GENSCSI.GSD

        Format:             	SCSI

        Manufacturers:      	Most SCSI drives on an Adaptec, Western Digital
                                WD7000 SCSI, Allway IN2000,Bitech 21xx, Sumo,
                                or most Future Domain SCSI boards.

        Hardware information required to configure device:
             SCSI Unit Number     Unit: 0, 1, 2, 3, 4, 5, 6, 7, auto (default)
             Host Adapter          Auto, Adaptec, WD/TNT, IN2000, Bitech 21xx
                                         Sumo, Future Domain




        Device name:        	GENSCSI2.GSD

        Format:             	SCSI 

        Manufacturers:      	Most SCSI drives on an Adaptec, Western Digital
                                WD7000 SCSI, Allway IN2000,Bitech 21xx, Sumo,
                                or most Future Domain SCSI boards.  Use this
                                driver if you are experience trouble with
                                the GENSCSI driver.

        Hardware information required to configure device:
             SCSI Unit Number     Unit: 0, 1, 2, 3, 4, 5, 6, 7, auto (default)
             Host Adapter          Auto, Adaptec, WD/TNT, IN2000, Bitech 21xx
                                         Sumo, Future Domain




        Device name:            INTERP.GSD

        Format:                 Parallel

        Manufacturers:          Any Interpreter drive running off of a
                                parallel port.

        Hardware information required to configure device:
             Parallel               auto (default), lpt1, lpt2, lpt3




        Device name:        	JUMBO250.GSD

        Format:             	QIC 80

        Manufacturers:      	Colorado Memory Systems drive with a 250MB
                                on the face plate. 
                                NOTE: We are not compatible with Colorardo's
                                Hardware compression cards.

        Hardware information required to configure device:
             Data Transfer Rate       	500K bps (default) 1000K bps




        Device name:        	Q02.GSD

        Format:             	QIC 02

        Manufacturers:      	EVEREX 811 CONTROLLER with any QIC 02 drive,
                       		e.g., Cipher, CMS Enhancements, Mountain,
                       		Tallgrass, and Wangtek.

        Hardware information required to configure device:
             Drive Number             	0, 1, 2, or 3
             Controller Port Address    300 (default), user selected
             Interrupt Channel        	IRQ3, IRQ4, IRQ5 (default), IRQ6, IRQ7
             DMA Channel Number      	Channel 1 (default), 2, or 3




        Device name:        	Q02ARCH.GSD

        Format:             	QIC 02

        Manufacturers:      	ARCHIVE SC402 CONTROLLER with any QIC 02 drive,
                       		e.g., Cipher, CMS Enhancements, Mountain,
                       		Tallgrass, and Wangtek.

        Hardware information required to configure device:
             Drive Number             	0, 1, 2, or 3
             Controller Port Address    300 (default), user selected
             Interrupt Channel        	IRQ3 (default), IRQ4, IRQ5, IRQ6, IRQ7
             DMA Channel Number      	Channel 1 (default), 2, or 3



        
        Device name:        	TEACSCSI.GSD

        Format:             	SCSI

        Manufacturers:      	ANY TEAC SCSI drive on an Adaptec, Western
                                Digital WD7000 SCSI, Allway IN2000, Sumo
                                or most Future Domain SCSI boards.

        Hardware information required to configure device:
             SCSI Unit Number     Unit: 0, 1, 2, 3, 4, 5, 6, 7, auto (default)
             Host Adapter          Auto, Adaptec, WD/TNT, IN2000, Bitech 21xx
                                         Sumo, Future Domain




        Device name:            VALITEK.GSD

        Format:                 Parallel/Serial

        Manufacturers:          Any Valitek drive running off of a parallel
                                or serial port.

        Hardware information required to configure device:
             Baudrate                   19.2k, 57.6k, 115.2k (default)
             Serial Port                COM1, COM2, COM3, COM4, NONE (default)
             Parallel                   LPT1 (default), LPT2, LPT3, NONE
             CPU Speed                  PC/XT
                                        AT 286/386sx 16mHz
                                        386/20
                                        386/25
                                        386/33 (default)



        Device name:        	WT40.GSD

        Format:             	QIC 40

        Manufacturers:      	Alloy, Wangtek, Techmar, some others.

        Hardware information required to configure device:
             Drive Location           	A, B (default) or PHANTOM (3rd drive)
             Data Transfer Rate       	250K bps or 500K bps (default)
             Controller Port Address    3F0 (default), user selected
             IRQ Interrupt Number       IRQ3, IRQ4, IRQ5, IRQ6(default), IRQ7
             DMA Channel Number       	Channel 1, 2 (default), or 3



        Device name:        	WT80.GSD

        Format:             	QIC 80

        Manufacturers:      	Alloy, Mountain, Archive, Wangtek, Techmar,
                     		some others.

        Hardware information required to configure device:
             Drive Location           	A, B (default) or PHANTOM (3rd drive)
             Data Transfer Rate       	500K bps (default) 1000K bps
             Controller Port Address    3F0 (default), user selected
             IRQ Interrupt Number       IRQ3, IRQ4, IRQ5, IRQ6(default), IRQ7
             DMA Channel Number       	Channel 1, 2 (default), or 3

             

                          
        Device name:        	XBYTASPI.GSD

        Format:             	SCSI 8mm

        Manufacturers:      	Any Exabyte 8mm 8x00 drive using
                       		any Adaptec SCSI board with the ASPI 
                       		manager driver loaded.

        Hardware information required to configure device:
             SCSI Unit Number         	Unit 0, 1, 2, 3, 4, 5, 6, or 7.
