        Device name:        	4280.GSD

        Format:             	SCSI DAT

        Manufacturers:      	Any Storage tech 18 track system that uses
                                4280 tapes. On an Adaptec or Western
                                Digital SCSI board.

        Hardware information required to configure device:
             SCSI Unit Number         	Unit 0, 1, 2, 3, 4, 5, 6, or 7.
             LUN Logical Unit Number    Unit 0, 1, 2, 3, 4, 5, 6, or 7.
             Auto Loader                OFF or ON
             Starting loader posistion  0,1,2,3,4,5,6,7,8 or 9
             Host Adapter               Adaptec (ASPI) or WD/TNT (SDLP)



        Device name:        	ARCHDAT.GSD

        Format:             	SCSI DAT

        Manufacturers:      	Any Archive/Manyard Python DAT drive using
                       		any Adaptec SCSI board with the ASPI 
                       		manager driver loaded.

        Hardware information required to configure device:
             SCSI Unit Number         	Unit 0, 1, 2, 3, 4, 5, 6, or 7.



        
        Device name:        	COLORADO.GSD

        Format:             	QIC 40

        Manufacturers:      	Colorado Memory Systems, Tall Grass,
                                some Mountian drives.

        Hardware information required to configure device:
             Controller Port Address    3F0 (default), user selected
             IRQ Interrupt Number       IRQ3, IRQ4, IRQ5, IRQ6(default), IRQ7
             DMA Channel Number       	Channel 1, 2 (default), or 3
             Is an (AB 10) adapter card being used?   YES or NO



        Device name:        	COLORAD2.GSD

        Format:             	QIC 40,Qic 80

        Manufacturers:      	Colorado Memory Systems newer drives.
                                Often these drives have a 120 MB or a
                                250MB on the face plate. If you look on
                                the back or top of the drive you will
                                see a white label.  If this label states
                                that the F.W. (Firmware) revision is 40
                                or higher this is the correct driver for
                                your system.
                                NOTE: We are not compatible with Colorardo's
                                Hardware compression cards.

        Hardware information required to configure device:
             Controller Port Address    3F0(default), user selected
             IRQ Interrupt Number       IRQ3, IRQ4, IRQ5, IRQ6(default), IRQ7
             DMA Channel Number       	Channel 1, 2 (default), or 3
             Is an (AB 10) adapter card being used?   YES or NO




        Device name:        	EVERX36.GSD

        Format:             	QIC 36

        Manufacturers:      	EVEREX 831 CONTROLLER with any QIC 36 drive,
                       		e.g., Cipher, CMS Enhancements, Mountain,
                       		Tallgrass, and Wangtek.

        Hardware information required to configure device:
             Drive Number             	0 (default), 1, 2, or 3
             Controller Port Address    370 (default), user selected
             Interrupt Channel        	IRQ3 (default), IRQ4, IRQ5, IRQ6, IRQ7
             DMA Channel Number      	Channel 1 (default), 2, or 3




        Device name:        	GENDAT.GSD

        Format:             	SCSI DAT

        Manufacturers:      	Most DAT drives on an Adaptec, Western Digital
                                WD7000 SCSI, Allway IN2000,Bitech 21xx, Sumo,
                                or most Future Domain SCSI boards.

        Hardware information required to configure device:
             SCSI Unit Number     Unit: 0, 1, 2, 3, 4, 5, 6, 7, auto (default)
             Host Adapter          Auto, Adaptec, WD/TNT, IN2000, Bitech 21xx
                                         Sumo, Future Domain


             
        Device name:        	GENSCSI.GSD

        Format:             	SCSI

        Manufacturers:      	Most SCSI drives on an Adaptec, Western Digital
                                WD7000 SCSI, Allway IN2000,Bitech 21xx, Sumo,
                                or most Future Domain SCSI boards.

        Hardware information required to configure device:
             SCSI Unit Number     Unit: 0, 1, 2, 3, 4, 5, 6, 7, auto (default)
             Host Adapter          Auto, Adaptec, WD/TNT, IN2000, Bitech 21xx
                                         Sumo, Future Domain




        Device name:        	GENSCSI2.GSD

        Format:             	SCSI 

        Manufacturers:      	Most SCSI drives on an Adaptec, Western Digital
                                WD7000 SCSI, Allway IN2000,Bitech 21xx, Sumo,
                                or most Future Domain SCSI boards.  Use this
                                driver if you are experience trouble with
                                the GENSCSI driver.

        Hardware information required to configure device:
             SCSI Unit Number     Unit: 0, 1, 2, 3, 4, 5, 6, 7, auto (default)
             Host Adapter          Auto, Adaptec, WD/TNT, IN2000, Bitech 21xx
                                         Sumo, Future Domain




        Device name:        	HPDAT.GSD

        Format:             	SCSI DAT

        Manufacturers:      	Any Hewlett Packard DAT drive with the
                                Western Digital	WD7000 SCSI board.

        Hardware information required to configure device:
             SCSI Unit Number         	Unit 0, 1, 2, 3, 4, 5, 6, or 7.




        Device name:            INTERP.GSD

        Format:                 Parallel

        Manufacturers:          Any Interpreter drive running off of a
                                parallel port.

        Hardware information required to configure device:
             Parallel               auto (default), lpt1, lpt2, lpt3




        Device name:        	PYXTNT.GSD

        Format:             	SCSI DAT

        Manufacturers:      	Any PYX 100 or ARCH X 100 DAT drive with the
                                Western Digital	WD7000, or TNT 4x00 SCSI board.

        Hardware information required to configure device:
             SCSI Unit Number         	Unit 0, 1, 2, 3, 4, 5, 6, or 7.




        Device name:        	Q02.GSD

        Format:             	QIC 02

        Manufacturers:      	EVEREX 811 CONTROLLER with any QIC 02 drive,
                       		e.g., Cipher, CMS Enhancements, Mountain,
                       		Tallgrass, and Wangtek.

        Hardware information required to configure device:
             Drive Number             	0, 1, 2, or 3
             Controller Port Address    300 (default), user selected
             Interrupt Channel        	IRQ3, IRQ4, IRQ5 (default), IRQ6, IRQ7
             DMA Channel Number      	Channel 1 (default), 2, or 3




        Device name:        	Q02ARCH.GSD

        Format:             	QIC 02

        Manufacturers:      	ARCHIVE SC402 CONTROLLER with any QIC 02 drive,
                       		e.g., Cipher, CMS Enhancements, Mountain,
                       		Tallgrass, and Wangtek.

        Hardware information required to configure device:
             Drive Number             	0, 1, 2, or 3
             Controller Port Address    300 (default), user selected
             Interrupt Channel        	IRQ3 (default), IRQ4, IRQ5, IRQ6, IRQ7
             DMA Channel Number      	Channel 1 (default), 2, or 3




        Device name:        	TEACASPI.GSD

        Format:             	SCSI

        Manufacturers:      	Any TEAC SCSI drive using any Adaptec SCSI
                                board with the ASPI manager driver loaded.

        Hardware information required to configure device:
             SCSI Unit Number         	Unit 0, 1, 2, 3, 4, 5, 6, or 7.



        
        Device name:        	TEACSCSI.GSD

        Format:             	SCSI

        Manufacturers:      	ANY TEAC SCSI drive on an Adaptec, Western
                                Digital WD7000 SCSI, Allway IN2000, Sumo
                                or most Future Domain SCSI boards.

        Hardware information required to configure device:
             SCSI Unit Number     Unit: 0, 1, 2, 3, 4, 5, 6, 7, auto (default)
             Host Adapter          Auto, Adaptec, WD/TNT, IN2000, Bitech 21xx
                                         Sumo, Future Domain




        Device name:            VALITEK.GSD

        Format:                 Parallel/Serial

        Manufacturers:          Any Valitek drive running off of a parallel
                                or serial port.

        Hardware information required to configure device:
             Baudrate                   19.2k, 57.6k, 115.2k (default)
             Serial Port                COM1, COM2, COM3, COM4, NONE (default)
             Parallel                   LPT1 (default), LPT2, LPT3, NONE
             CPU Speed                  PC/XT
                                        AT 286/386sx 16mHz
                                        386/20
                                        386/25
                                        386/33 (default)



        Device name:        	WT150.GSD

        Format:             	SCSI 150

        Manufacturers:      	Any QIC 150 SCSI format tape drive using
                       		the Western Digital WD7000 SCSI board.

        Hardware information required to configure device:
             SCSI Unit Number         	Unit 0, 1, 2, 3, 4, 5, 6, or 7.



        Device name:        	W150ASPI.GSD

        Format:             	SCSI 150

        Manufacturers:      	Any QIC 150 SCSI format tape drive using
                       		any Adaptec SCSI board with the ASPI
                       		manager driver loaded.

        Hardware information required to configure device:
             SCSI Unit Number         	Unit 0, 1, 2, 3, 4, 5, 6, or 7.



        Device name:        	WT40.GSD

        Format:             	QIC 40

        Manufacturers:      	Alloy, Wangtek, Techmar, some others.

        Hardware information required to configure device:
             Drive Location           	A, B (default) or PHANTOM (3rd drive)
             Data Transfer Rate       	250K bps or 500K bps (default)
             Controller Port Address    3F0 (default), user selected
             IRQ Interrupt Number       IRQ3, IRQ4, IRQ5, IRQ6(default), IRQ7
             DMA Channel Number       	Channel 1, 2 (default), or 3



        Device name:        	WT80.GSD

        Format:             	QIC 80

        Manufacturers:      	Alloy, Mountain, Archive, Wangtek, Techmar,
                     		some others.

        Hardware information required to configure device:
             Drive Location           	A, B (default) or PHANTOM (3rd drive)
             Data Transfer Rate       	500K bps (default) 1000K bps
             Controller Port Address    3F0 (default), user selected
             IRQ Interrupt Number       IRQ3, IRQ4, IRQ5, IRQ6(default), IRQ7
             DMA Channel Number       	Channel 1, 2 (default), or 3



        Device name:        	XBYTASPI.GSD

        Format:             	SCSI 8mm

        Manufacturers:      	Any Exabyte 8mm 8x00 drive using
                       		any Adaptec SCSI board with the ASPI 
                       		manager driver loaded.

        Hardware information required to configure device:
             SCSI Unit Number         	Unit 0, 1, 2, 3, 4, 5, 6, or 7.


        
        Device name:        	XBYTSDLP.GSD

        Format:             	SCSI 8mm

        Manufacturers:      	Any Exabyte 8mm 8x00 drive using
                       		the Western Digital WD7000 SCSI board.

        Hardware information required to configure device:
             SCSI Unit Number         	Unit 0, 1, 2, 3, 4, 5, 6, or 7.
